SUPER MICRO Computer 6014H-8 user manual Power Fail Detect, SMB I2 C Connector, Overheat LED JOH1

Models: 6014H-8

1 130
Download 130 pages 57.82 Kb
Page 55
Image 55

Chapter 5: Advanced Serverboard Setup

Power Fail Detect

Connect a cable from your power supply to the Power Fail header (JP9) to provide warning of power supply failure. This warning sig- nal is passed through the PWR_LED pin to indicate on the control panel that a power supply has failed. See the table on the right for pin definitions.

Power Fail

Pin Definitions (JP9)

Pin

Definition

Number

1

P/S 1 Fail Signal

2

P/S 2 Fail Signal

3

P/S 3 Fail Signal

4

Reset (from MB)

 

 

Note: This feature is only available when

using redundant Supermicro power supplies.

SMB (I2 C) Connector

An I2C connector at J11 (located near the battery on the X6DHR- 8G2 and near the IPMI header on the X6DHR-8G/X6DHR-X8G) moni- tors the status of the PWR supply, the fans and the system tempera- ture.

SMB PWR

Pin Definitions (J27)

Pin #

Definition

1

Clock

2

SMB Data

3

N/A

4

N/A

5

N/A

 

 

Overheat LED (JOH1)

Connect an LED to the JOH1 header to provide warning of chassis overheating. See the table on the right for pin defini- tions.

Overheat LED

Pin Definitions (JOH1)

Pin

Number Definition

1+5V

2OH Active

GLAN1/2 (Ethernet Ports)

Two gigabit Ethernet ports (desig- nated GLAN1 and GLAN2) are lo- cated on the I/O backplane. These ports accept RJ45 type cables.

5-19