NovaJet 500/630/700 Series Service Manual
Figures 3-4 and 3-5 shows the locations of all the connectors on the MPWA and carriage board respectively. To remove the ribbon cables from their connectors, lift the connector’s ribbon locking mechanism as shown in figure 3-6. To reattach, depress the locking mechanism back into the locking position after inserting the ribbon cable end.
RIBBON
LOCKING
MECHANISM
UNLOCKED
LOCKED
CONNECTOR
ASSEMBLY
Figure 3-6. Ribbon Connector Locking Mechanism.
Replace Carriage Bushings
The carriage bushings are rated for approximately 1500 hours of operational usage. Many factors including, but not limited to, hours/ day used, cleanliness of the slide shaft and general ambient environ- ment make it impossible to calculate the average time that the carriage bushings to last.
If not replaced, the wear on the bushings can result in erratic carriage motion and/or carriage axis failures. It can even cause the cartridge head height to become uneven.
To replace the carriage bushings, follow the procedures for Carriage Bushing Replacement found in Chapter 5.