3.Place the test cartridge upright on a flat surface and ‘zero’ the gauge by loosening the knob near the top and turning the dial until the needle is at the ‘0’ position on the dial. Tighten the knob. See Figure 3-16.

ZERO

ENSURE PRESSURE IS

PLACED ON THE REAR

GAUGE

OF THE CARTRIDGE

 

Figure 3-16. Zeroing the Micrometer Gauge.

4.Remove the Cyan ink cartridge. Snap the test cartridge with the micrometer gauge into the position vacated by the Cyan ink cartridge. See Figure 3-17. Ensure that the micrometer can be read from the BACK of the printer.

Figure 3-17. Test Cartridge Installed.

MAINTENANCE

Maintenance 3-23

Page 65
Image 65
Kodak 700, 630, 500 service manual Zero Ensure Pressure is Placed on the Rear Gauge Cartridge