NovaJet 500/630/700 Series Service Manual
4.Remove the air filter from the fan to be removed by squeezing the tabs on the filter housing to release the housing off the fan.
5.Remove the four bolts securing the back bracket (the one with the positioning bolts on the bottom) to both of the side plates.
6.Pull the back bracket away from the fans to gain access to the faulty fan. Carefully pull the fan away from the front bracket until access is gained to reach the electrical connector.
7.Disconnect the connector to the fan.
Install the Media Drying Fans
1. | Reconnect the electrical connection to the fan. Push the connector |
|
| and wires into the bracket so the fan can be seated correctly on the |
|
| bracket. |
|
2. | Carefully orient all the fans so that the back bracket can be |
|
| installed correctly. Secure the back bracket to the side plates. |
|
3. | Install the air filter and air filter housing. |
|
4. | Lay the entire assembly onto the support brackets on the printer. |
|
| Ensure that the cable connector is on the right side of the printer as |
|
| it is installed. |
|
5. | Reattach the positioning wingnut on the left side of the assembly. |
|
6. | Attach the wire connector to the leg harness plug. Push connector |
|
| in until firmly seated. |
|
| ASSEMBLY/ DISASSEMBLY | |
|
| |
|
|
|