NovaJet 500/630/700 Series Service Manual
2.From the Utility Menu, select “Color Calib Menu”. This brings up the color calibration menu and it looks like Figure
Cyan Vertical | * | Cyan Horizontal |
Magenta Vertical |
| Magenta Horizontal |
Yellow Vertical |
| Yellow Horizontal |
Calib Print Test |
| Exit |
Figure 3-21. Color Calib Menu.
3.Select “Calib Print Test” to print the color calibration plot as shown in Figure
4.When the plot is complete, select “Cyan Vertical” at the Color Calib Menu. This brings up the options menu for the cyan vertical adjustment as shown in Figure
Cyan Vertical | * | Cancel |
Next Option |
|
|
<selected> |
|
|
Prev Option |
| Ok |
Figure 3-22. Cyan Vertical Options Menu.
5.Observe the plot and using either “Prev Option” or “Next Option”, rotate through the selections until the one that best aligns the cyan color on the plot is selected. Press “Ok” to accept the selection and return to the Color Calib Menu.