NovaJet 500/630/700 Series Service Manual
Head Height Alignment Procedure
Perform this procedure only when the encoder strip stabilizer has been removed from the
The head height alignment procedure is to ensure that the correct amount of distance exists between the cartridge jet plate and the Platen. See Figure
CARTRIDGE
JET PLATE
PLATEN
HEAD HEIGHT
Figure 3-14. Carriage Head Height Tolerance.
1.Remove the lid and the right cover of the printer. See Chapter 5 for procedures.
2.Obtain the 3 tools (Micrometer Dial Gauge, Test Cartridge, and Measuring Tip Extender) from the Height Gauge Kit. Assemble the tools as shown in Figure
SPIN HEAD ON |
|
MICROMETER GAUGE | MICROMETER |
TO FACE BACKWARDS | DIAL GAUGE |
TIGHTEN SET
SCREWS
TEST CARTRIDGE
MEASURING
TIP EXTENDER
ENSURE TIP EXTENDS BELOW CARTRIDGE 1/4" (6mm)