NovaJet 500/630/700 Series Service Manual
Black Deadband | * | Color Db Test |
Cyan Deadband |
|
|
Magenta Deadband |
|
|
Yellow Deadband |
| Exit |
Figure 3-28. Color Db Menu.
Select “Color Db Test” to run the color deadband test.
The test consists of 12 default calibration settings. When the test is run it will print out a pattern of 5 calibration lines for each of the 12 settings. It will print this pattern in black first, followed by cyan, magenta and then yellow. Also printed will be the current settings for each of the four colors as well as the slow deadband setting.
5.When the plot is complete, select “Black Deadband” at the Color Db Menu. This brings up the options menu for the black deadband adjustment. This menu is similiar to the menu depicted in Figure
NOTE
The only acceptable values for the color deadband adjustments are 12, 20, 28, 36, 44, 52, 60, 68, 76, 84, 92 and 100. Any other value entered will ap- pear to be accepted because it will be displayed in the current settings section the next time this test is run. In actuality, the system will default to the closest allowable setting as listed above.