76 Intel Server Board SE7500WV2 Product Guide
Table 15. Extended POST Error Messages and Codes
Error Code Error Message Pause on Boot
8100 Processor 1 failed BIST No
8101 Processor 2 failed BIST No
8110 Processor 1 Internal error (IERR) No
8111 Processor 2 Internal error (IERR) No
8120 Processor 1 Thermal Trip error No
8121 Processor 2 Thermal Trip error No
8130 Processor 1 disabled No
8131 Processor 2 disabled No
8140 Processor 1 failed FRB-3 timer No
8141 Processor 2 failed FRB-3 timer No
8150 Processor 1 failed initialization on last boot. No
8151 Processor 2 failed initialization on last boot. No
8160 Processor 01: unable to apply BIOS update Yes
8161 Processor 02: unable to apply BIOS update Yes
8170 Processor P1 :L2 cache Failed Yes
8171 Processor P2 :L2 cache Failed Yes
8180 BIOS does not support current stepping for Processor P1 Yes
8181 BIOS does not support current stepping for Processor P2 Yes
8190 Watchdog Timer failed on last boot No
8191 4:1 Core to bus ratio: Processor Cache disabled Yes
8192 L2 Cache size mismatch Yes
8193 CPUID, Processor Stepping are different Yes
8194 CPUID, Processor Family are different Yes
8195 Front Side Bus Speed mismatch. System Halted Yes, Halt
8196 Processor Model are different Yes
8197 CPU Speed mismatch Yes
8300 Baseboard Management Controller failed to function Yes
8301 Front Panel Controller failed to Function Yes
8305 Hotswap Controller failed to Function Yes
8420 Intelligent System Monitoring Chassis Opened Yes
84F1 Intelligent System Monitoring Forced Shutdown Yes
84F2 Server Management Interface Failed Yes
84F3 BMC in Update Mode Yes
84F4 Sensor Data Record Empty Yes
84FF System Event Log Full Yes