The Continuous Test will first prime the cartridges, followed by a serial port test, parallel port test, a fast deadband display and a color calibration display.

The deadband and color calibration displays are used only as a visual inspection of the operating condition of the printer. No adjustments can be performed while in the Continuous Test mode.

A loopback Test Cable is required to correctly accomplish the serial and parallel port tests. Install both ends of the Loopback Cable before running this test. The Loopback Test Cable is listed in Chapter 6.

After completing the deadband display, the test will begin again with the prime and continue until power is removed.

Fan #1 and Fan #2 Tests - Tests the operation of the fans on the printer. Fan #1 Test (while depressed) turns on the power supply cooling fan and the suction fan inside the platen on the right side of the printer. Fan #2 Test (while depressed) turns on the suction fan inside the platen near the center of the printer. The 42 inch printer does not have this second suction fan, therefore, the Fan #2 Test is disabled.

Legs Test - Tests the condition of the leg harness connections and the components of the power feed and take-up system.