SUPERSERVER
3rd Power Supply Fail Detect Enable/Disable
The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one act- ing as a backup. If you only have one or two power supply units installed, you should disable this (the default setting) with J3P to prevent false alarms. See the table on right for pin definitions.
Note: J3P should be disabled on the
JLAN Enable/Disable
Change the setting of jumper JPL1 or JPL2 to enable or disable the onboard Ethernet (RJ45) ports JLAN1 and JLAN2, respectively. See the table on the right for jumper settings. The default setting is enabled
Watch Dog Enable/Disable
JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application is “hung up”. Pins
Note: When enabled, the user needs to write their own application software to disable the Watch Dog Timer.
3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P)
Jumper Setting |
| Definition |
Open |
| Disabled |
| ||
Closed |
| Enabled |
| ||
|
|
|
JLAN Enable/Disable
Jumper Settings (JPL1, JPL2)
Jumper Setting |
| Definition |
Pins |
| Enabled |
| ||
Pins |
| Disabled |
| ||
|
|
|
Watch Dog
Jumper Settings (JWD)
Jumper Setting |
| Definition |
Pins |
| Reset |
| ||
Pins |
| NMI |
| ||
Open |
| Disabled |
| ||
|
|
|