2.Ensure that the D6i is turned on, and that the wireless integration is enabled in the Suunto D6i settings (Tank Press is set ON. For more information, refer to Section 5.9.3. Setting the tank pressure pairing). If the D6i is in the TIME mode, enter the DIVE mode by short-pressing the MODE button. The D6i should display “cd:--” in the lower left corner of the display.

3.Slowly open the cylinder valve fully and pressurize the system. The transmitter starts transmitting when the pressure exceeds 15 bar/300 psi.

4.Take the Suunto D6i unit close to the transmitter. The unit will then quickly display the selected code number and then start displaying the transmitted cylinder pressure. The wireless transmitter indicator (flash symbol) is displayed every time the Suunto D6i receives a valid signal.

WARNING

If there are several divers using Suunto D6i with wireless trans-

 

mission, always ensure that each diver is using a different code

 

before starting the dive. In case there are several divers using

 

the same code, the transmitter's code must be changed before

 

diving.

To assign a new transmitter code:

1.Slowly open the cylinder valve fully to pressurize the system.

2.Close the valve. Depressurize the regulator so that the pressure is reduced to less than 10 bar/145 psi. Wait about 10 seconds, and slowly open the cylinder valve again to re-pressurize to above 15 bar/300 psi.

The transmitter assigns a new code automatically.