5-16
MK1000 MicroKiosk Product Reference Guide
<0xFF> = The beep code. The scanner’s beeper output is not monitored. 0xFF
indicates no beep, and it should be set to 0xFF.
<Parameter> = Any valid SSI ParamSend value.
<ParamData> = Any valid SSI ParamSend data value.
Redirecting Data To The Serial PortESC[B<Data For Auxiliary Port> redirects data to the Serial port. All data followi ng this
command up to the end of the current packet is sent out the auxiliary port. Data is s ent "as
is" without processing, except for the Shift Out/In control c odes, to allow the host to send
all 256 possible codes to the auxiliary port.
Note:When the MK1000 is running in PCK emulation mode, data received
on the Auxiliary port is sent to the host. It is sent in packets, up to a
maximum of 128 bytes, as the data is received. It is framed
according to the current Software Handshaking Type setup in the
unit.
Beep CommandsESC[PbS sounds the beeper.
Pb is the beep code parameter that is, the beep code value specifi ed in ASCII digits (see
the table below).
Table 5-8. Beep Sequences
Decimal Value Beep Sequence
0 1 Short High Beep
1 2 Short High Beeps
2 3 Short High Beeps
3 4 Short High Beeps
4 5 Short High Beeps
5 1 Short Low Beep
6 2 Short Low Beeps