2-7
Setup and Installation: Mechanical
To install the MK1000 with a host that does not support RS-485, follow the instructions
below.
1. Provide power to the MK1000 using its power supply.
Insert the round barrel connector at the end of the power supply cable into the
MK1000’s Power port. (See Figure 1-1 on page 1-3 for port locations.)
Plug the power supply into a wall outlet.
2. Connect the conversion box to the host using an RS-232 cable.
3. Attach the RS-485 Serial cable.
Connect the RS-485 Serial cable to the LAN port on the MK1000. (See Figure
1-1 on page 1-3 for port locations.) Ensure the Serial cable is terminated
according to the RS-485 Connectors - LAN Port described in Table 2-5.
Plug the other end of the RS-485 Serial cable into the converte r box.
4. To mount the MK1000, see Mounting the MK1000 on page 2-11.
After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and
Installation: Communication to establish communication with the host.