5-97
Parameter Menus
Scanner AddressScan the following barcode, followed by 3 digits from the numeric barcode section (starting
on page 5-101), to set the address of th e scanner (scanner ID).
The number of scanner addresses (scanner ID’s) varies with the selected communication
protocol.
•RS-232/Synapse range from 001 to 254
•MCL Link Lite (MCL Net) range from 001 to 0 0 2
•MCL Link (MCL Net) range from 001 to 254
SCANNER ADDRESS
MCL-Net Transmit RetriesScan the following barcode, followed by 2 digits from the numeric barcode section (starting
on page 5-101), to define the number of retries in the range 1 to 10.
MCL-NET RETRIES
MCL-Net Frame TimeoutScan the following barcode, followed by 2 digits from the numeric barcode section (starting
on page 5-101), to define the amount of time to wait for an ACK or NAK from the host before
retransmitting. The timeout is in 100 ms increme nts in the range 100 ms to 3000 ms.
MCL-NET FRAME TIMEOUT