| TacT M/S2150 Software |
|
| |
| Connect your | Your M/S2150 must be connected to your computers serial port in order for it to |
| M/S2150 to your | communicate with your computer when you run the M/S2150 software. Please fol- |
| Computer | low the steps below to connect your M/S2150 to your computer. |
|
| 1 - Connect the RS 232 “Input” jack on the back of the M/S2150 to your |
|
| computers serial port using the supplied cables and adapters. Your computer |
|
| must have a standard RS 232 serial port with a DB 9 connector. |
|
| NOTE: If you have any other Tact digital amplifiers please disconnect their |
|
| RS232 connection at this time. |
|
| 2 - Turn on your M/S2150. |
|
| 3 - Turn on your computer and start the M/S2150 System Software. |
|
| NOTE:You may receive a communication error message. Please close the mes- |
|
| sage window and proceed to the next step. |
|
| 4 - Select the “Com” button on the main software screen to open the communica- |
|
| tion window. |
|
| 5 - Under the Operating Mode select “Connect”. |
|
| 6 - Under the COM Port section select “COM1”. If you receive an “invalid |
|
| port number” message please try selecting each of the port selections until |
|
| you do not receive this message. If you receive this message on all COM ports |
|
| you may not have a COM port installed on your computer. Please refer to your |
|
| computer manufactures documentation for help to install a COM port. |
|
| 7 - To verify that M/S2150 is properly connected to the host computer click on |
|
| the “Start” button to perform the communication test. If everything is |
|
| functioning properly you should see the results below. Press the “Stop” |
|
| button after about 15 seconds to stop the test. |
|
| Rx Buf should display “0”. |
|
| Count should have counted in increments of 100. |
|
| Err Count should be “0”. |
|
| If the results are as above select the “Close” button to close the communication |
|
| window. Your M/S2150 is now connected to your computer. |
|
| If the results are not as above please go back to step number 6 and select |
|
| another COM port. Then repeat step 7. |
|
| NOTE: If you are still are not passing the communication test you may not |
|
| have a COM port installed on your computer or you may have another de- |
|
| vice such as a modem or hand held PC that may be sharing the COM port |
|
| on your computer. If you have a other Tact equipment attached it may be |
|
| set to the same address. The M/S2150 requires a valid COM port that is not |
|
| being used by any other devices. |
|
| NOTE: You will only have to select the communication port once. The next |
|
| time you run the M/S2150 correction software it will remember your set- |
28 Tact Audio | tings. |