15
ModelsH71 & H84 Important:To the Operator
H84 Screen:
OFF :MODE: OFF
OK :MIX: OK
40.0F HOPPER 40.0F
BRUSHCLEAN ON: MM/DD
The next display indicates the freezer is operating in
two different modes. The following informat ion is
given:
The machine is operating in the WASH mode, the
temperatureof t he mix hopper is 40_F(4.4_C),andthe
machine needs to be brush cleaned on October 31st.
H71 Screen:
MODE:WASH
HOPPERTEMP: 40.0 F
BRUSHCLEAN ON: 10/31
H84 Screen:
Thenext display indicates the fr eezer is operating in 3
different modes. The following information is given:
The left side of the freezer is operating in t he
STANDBY mode, and the mix level in the hopper is
OUT.T he right side is operating in the WASH mode,
and the mix level in the hopper is LOW. The
temperature of the mix in both hoppers is 40_F.
(4.4_C.), and the machine needs to be brush cleaned
on October 31st.
STANDBY :MODE: WASH
OUT :MIX: LOW
40.0F HOPPER 40.0F
BRUSHCLEAN ON: 10/31
The followingdisplays pertain to the HEAT cycle:
While in the heating phase, you will see this display. It
shows the present temperature of the hopper.
H71 Screen:
MODE:HEAT
PHASE:HEAT
HOPPERTEMP: 140.0 F
BRUSHCLEAN ON: MM/DD
H84 Screen:
HEAT :MODE: HEAT
HEAT :PHASE: HEAT
140.0F HOPPER 140.0F
BRUSHCLEAN ON: MM/DD
CAUTION: DO NOT draw product or
attempt to disassemble the unit d uring the HEAT
cycle. The product is hot and under extreme
pressure.
The mix temperature must be raised above 151_F
(66.1_C)within 90 minutes or t he freezer will be locked
inSTANDBY, and the cycle failure display will appear.
In the example, the hopper temperature is 140_F
(60_C). The phase shows that the machine is in the
heat phase of the heat treatment cycle.
Whenthe heat ing phase is complete, the freezer goes
into the holdingphase of t he cycle.T he holding phase
will hold the temperature above 151_F (66.1_C) for a
minimum of 30 minutes.
In this example, the hopper temperature is 151_F
(66.1_C).
H71 Screen:
MODE:HEAT
PHASE:HOLD
HOPPERTEMP: 151.0 F
BRUSHCLEAN ON: MM/DD
H84 Screen:
HEAT :MODE: HEAT
HOLD :PHASE: HOLD
151.0F HOPPER 151.0F
BRUSHCLEAN ON: MM/DD