19
ModelsH71 & H84 Important:To the Operator
Screen“C” is SET CLOCK.This screen will display the
current date and time. The date and time may be
changed only after the freezer has been manually
brush cleaned, but before it has been placed in the
AUTO mode. Move the cursor under the number you
wish to change. Press the plus key to increase the
number; press the minus key to decrease the number.
When the desired time and date appears, press the
SEL key once to return to the OPERATOR MENU.
SETCLOCK
10:21AM 06/07/2001
-- --
<------> +++ ---- -- SEL
If an illegal date is entered, the following screen will
appear. The correct date must be entered before
leaving this display.
SETCLOCK
10:34AM 02/30/2002
-- -- IN V A L I D D AT E
<------> +++ ---- -- SEL
Screen “D” is SYSTEM INFORMATION. The first
screen will indicate the software version used in the
unit.
SOFTWAREVERSION
H71ControlUVC2
Version 2.00
SEL
Press the SEL key to view the second screen of the
SYSTEM INFORMATION display. This screen will
indicate the language, version number and language
strings used in the unit.
Language
V1.10r00 English459
SEL
Press the SEL key to view the third screen of the
SYSTEM INFORMATION display. This screen will
indicate the Bill of Material number and serial number
of the unit. Press the SEL key once to return to the
OPERATORMENU.
B.O.M. PH7133B000
S/N K0000000
SEL
Screen “E” is AUTO HEAT TIME. This screen is used
toset t he time of day in which the heat treatment cycle
willst art. Move the cursor under the number y ou wish
tochange. Press the plus key to increase the number;
press the minus key to decrease the number. When
the desired time appears, press the SEL key once t o
returnto the OPERATOR MENU.
AUTOHEAT TIME
TIME: 12:00 AM
-- --
<------> +++ ---- -- SEL
Screen “F” is CURRENT CONDITIONS. This s creen
gives the viscosity of the product and the hopper and
barrel temperatures. The last line of the display is the
compressor countdown safety timer. The safety timer
prevents the compressor from running more than 11
minutes (other than during the cooling phase of the
heat treatment cycle).
Press the SEL key once to view the SERVINGS
COUNTER screen.
H71 Screen:
VISC HOPPER BARREL
0 38.5 28.5
TIMEC 11:00 11:00
H84 Screen:
VISC HOPPER BARREL
0 38.5 28.5
0.0 38.5 18.0
TIMEC 11:00 11:00