31
ModelsH71 & H84 OperatingProcedures
Step 1
When the heating cycle is complete, the normal dis-
play will appear, showing the machine in the STAND-
BYmode. Pr epare a small amount of an approved 100
PPM sanitizing solution (example: Kay-5r). USE
WARMWATER AND FOLLOW THE MANUFACTUR-
ER’S SPECIFICATIONS.
Sanitize the design caps, air orifices, front drip tray,
and the splash shield in this solution.
Step 2
Return to the freezer with a small amount of sanitizing
solution. Dip the end brush into the sanitizing solution
andbrush clean the door s pout and bottom of the draw
valve.
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the brush in sanitizing solution.
Step 3
Rinse a single service towel in sanitizing solution and
wipe down the freezer door and area around the
bottom of the freezer door.
Replace the design caps, air orifices, front drip tray
and the splash shield.
MAKE SURE YOUR HANDS ARE SANITIZED
BEFORE PERFORMING THIS NEXT STEP!
Step 4
Lift the hopper cover and turn the inner air tube of the
assembled air tubes so the pin rests at the bottom of
the notch of the outer air tube.
12155
Figure 32
Step 5
Press the AUTO key to resume normal operation.
When the unit cycles off, product is ready to serve.
Manual Brush Cleaning
THIS PROCEDURE MUST BE DONE EVERY 14
DAYS!
ALWAYSFOLLOW LOCAL HEALTHCODES.
To disassemble your unit, the following items will be
needed:
STwo cleaning pails
SNecessary brushes (provided with freezer)
SCleaning solution
SSingle service towels

Draining ProductFrom The Freezing

Cylinder

Step 1
Press the AUTO key, cancelling compressor and
beater motor operation.
Step 2
Removethe hopper cov er,agitat or,and ass embled air
tube from the mix hopper. Takethese part st o thes ink
for cleaning.
Step 3
With apail under the door spout, pressthe WASH key.
Open the draw valve and drain the remaining product
from the freezing cylinder and mix hopper.
Step 4
When the flow of product stops, press the WASH key,
cancelling the wash cycle and close the draw valve.
Discard this product.
Repeat Steps 1 through 4 for the other side of the
freezer on the Model H84.