SETUPS

Fig 4

Fig 5

Fig 6

SYNC IN

ANALOG

D22

DIGITAL

IN

Digital Device

DIGITAL

D22

DIGITAL

IN

Digital Device

Local Wordclock

DIGITALREF

SYNC IN fr om Remote Clock

D22

SYNC IN

DIGITAL

IN

Digital Device

Input: Analog

Sample Rate: Sync.

Output: AES or S/PDIF

Dither: Same as the resolution on the device after the D22.

Installation note:

Wordclock Inputs on the D22 and the down- stream device may be used to enable jitter rejection.

Input: Digital

Sample Rate: EXT DI

Output: AES or S/PDIF

Dither: Same as the resolution on the device after the D22.

Installation note:

Wordclock Inputs on the D22 and the down- stream device may be used to enable jitter rejection.

Input: Digital

Sample Rate: Sync.

Sample Rate Conversion: On

Output: AES or S/PDIF

Dither: Same as the resolution on the device after the D22.

If using both the digital Input and the Sync Input, these must be syncronized.

The Sample Rate on the device after the D22 must be taken from its digital Input unless the Sync Input on this device is used.

11

Page 13
Image 13
TC electronic SDN BHD D22 user manual Input Analog Sample Rate Sync, Input Digital Sample Rate EXT DI