UTILITY

RS485 CTRL.

Remote control of Preset change, Delay time and Bypass is implemented in the D22 by using a RS485 controller.

All remote control capabilities are enabled/disabled by the REMOTE key. All displays and key states are updated according to incoming remote control info, i.e. the Delay time on the Recall page is always indicating the actual Delay.

The command structure for a Program change is: #AA,<PRE>,<NUM><CR>

The command structure for changing Delay time is: #AA,<DEL>,<delay in current mode><CR>

The command structure for changing Bypass mode is: #AA,<BYP>,<0/1><CR>

CR=ASCII 13

Pinout of the 5-pin DIN connector:

(All three connectors carry the same RS485 I/O capability) Data + : Pin no 3

Data - : Pin no 1

Common : Pin no 2 (Only on Thru and output connectors.)

Program Change

The RS485 implementation in the D22 is a “command receive only” type.

On

: Program changes from a RS485 controller will be

 

recognized.

Off

: Program changes from a RS485 controller will be

 

ignored.

Address

The D22 unit RS485 address number.

Memory Backup

RAM to Card - Press OK

This action will dump all presets to the RAM card. WARNING ! All previous information on the card will be destroyed.

RAM Protect - ON/OFF

Turn the ADJUST wheel to activate the RAM protect function. With the RAM protect function activated you can not delete or overwrite RAM presets.

Card to RAM - Press OK

Copies all presets from the PCMCIA card to the internal RAM bank.

Note! All presets in the internal RAM bank will be deleted.

_____________________________________________________

GPI - (External Input)

Use a:

 

Digital Fader

- for digital fade on the Output.

Momentary switch

- for tap Delay time

Alternating switch

- for activating/deactivating Bypass mode.

_____________________________________________________

Meter

Selects whether the meters should show Input or Output levels.

20

Page 22
Image 22
TC electronic SDN BHD D22 user manual Memory Backup, GPI External Input, Meter