Command Descriptions
TDS Family Oscilloscope Programmer Manual 2–327
TRIGger : :VIDeo
MAIn ?
FLEXformat
:
TRIGGER:MAIN:VIDEO:FLEXFORMAT?
might return: 59.94E+0;1050;2;890.0E-9;3.56E-6;15.00E-6;11.56E-6;
15.89E-6 as the flexible-format video trigger parameters.
TRIGger:MAIn:VIDeo:FLEXformat:FIELDRATE
TDS 510A, 500C, 600B, & 700C Option 05 Only
Sets or queries the flexible-format video frames per second (e.g. 59.94 frames
per second for 1050 and 50 for 1250). This is equivalent to selecting Setup from
the video main menu (with FlexFmt as the Standard), Field Rate from the side
menu, and entering a value with the keypad or the general purpose knob.
Trigger
TRIGger:MAIn:VIDeo:FLEXformat:FIELDRATE <NR3>
TRIGger:MAIn:VIDeo:FLEXformat:FIELDRATE?
FIELDRATE
?
<Space> <NR3>
TRIGger : :VIDeo
MAIn : FLEXformat :
<NR3> the field rate.
TRIGGER:MAIN:VIDEO:FLEXFORMAT:FIELDRATE?
returns the specified field rate.
TRIGger:MAIn:VIDeo:FLEXformat:FIELDS
TDS 510A, 500C, 600B, & 700C Option 05 Only
Sets or queries the flexible-format video fields. This is equivalent to pressing
Setup from the video main menu (with FlexFmt as the Standard), Fields from
the side menu, and entering the value with the keypad or the general purpose
knob.
Trigger
Examples
Group
Syntax
Arguments
Examples
Group