Table 3-13. Switch Two Settings – 2185 A

 

 

 

 

 

 

Switch

 

 

 

 

 

Segment

Setting

 

 

Reason

 

 

 

 

 

 

2-1

Up

 

 

Control Signal Contention

 

 

 

 

 

 

2-2

Down

 

 

Asynchronous operation

 

 

 

 

 

 

2-3

XX

 

 

Does not matter; on for sync only

 

 

 

 

 

 

2-4

XX

 

 

Depends on line conditions

 

 

 

 

 

 

2-5

XX

 

 

Does not matter, since unit is set

 

 

 

 

for async. operation

2-6

XX

 

 

 

 

 

 

 

 

 

 

 

2-7

Down

 

 

RTS/DCD on all the time

 

 

 

 

 

 

2-8

XX

 

 

Does not matter (Main Ch DTE)

 

 

 

 

 

Table 3-14. Switch Three Settings – 2185 A

 

 

 

 

 

 

Switch

 

 

 

 

 

Segment

Setting

 

 

Reason

 

 

 

 

 

 

3-1

Up

 

 

Main Channel connection to DTE

 

 

 

 

 

 

3-2

Up

 

 

Subchannel one connection to DTE

 

 

 

 

 

 

3-3

Down

 

 

Subchannel two connection to DCE

 

 

 

 

 

 

3-4

XX

 

 

Subchannel three not used

 

 

 

 

 

 

3-5

XX

 

 

Subchannel four not used

 

 

 

 

 

 

3-6

XX

 

 

Subchannel five not used

 

 

 

 

Table 3-15. Switch One Settings – 2185 B

 

 

 

 

 

 

Switch

 

 

 

 

 

Segment

Setting

 

 

Reason

 

 

 

 

 

 

 

1-1

Down

 

 

Enable Subchannel 1

 

 

 

 

 

 

 

1-2

Down

 

 

Enable Subchannel 2

 

 

 

 

 

 

 

1-3

Down

 

 

Enable Subchannel 3

 

 

 

 

 

 

 

1-4

Down

 

 

Enable Subchannel 4

 

 

 

 

 

 

 

1-5

Down

 

 

Enable Subchannel 5

 

 

 

 

 

 

 

1-6

Up

 

 

The settings of these three

 

 

 

 

 

switches set the data rate

 

1-7

Up

 

 

 

 

 

(1. 2 kpbs)

 

 

 

 

 

 

1-8

Down

 

 

 

 

 

 

 

 

 

 

3-24