Telenetics 2185

Table 3-16. Switch Two Settings – 2185 B

Switch

 

 

Segment

Setting

Reason

 

 

 

2-1

Down

Data Contention

 

 

 

2-2

Down

Asynchronous operation

 

 

 

2-3

XX

Does not matter, since the unit is on for

 

 

sync only

 

 

 

2-4

XX

Depends on line conditions

 

 

 

2-5

XX

Doesn't matter, since the unit is set for

 

 

async. operation

2-6

XX

 

 

 

 

2-7

Down

RTS/DCD on all the time

 

 

 

2-8

Up

CTS on all the time

 

 

 

Table 3-17. Switch Three Settings – 2185 B

Switch

Setting

Reason

 

 

 

3-1

Down

Main Channel connection to DCE

 

 

 

3-2

Up

Subchannel one connection to DTE

 

 

 

3-3

Up

Subchannel two connection to DTE

 

 

 

3-4

Down

Subchannel three connection to DCE

 

 

 

3-5

Up

Subchannel four connection to DTE

 

 

 

3-6

Down

Subchannel five connection to DCE

 

 

 

3-25

Page 47
Image 47
Telenetics manual Switch Two Settings 2185 B, Switch Three Settings 2185 B