Telit Wireless Solutions GE863-QUAD, GE863-PY manual Number Pad Number, Ground 45-48-50-56

Models: GE863-QUAD GE863-PY

1 79
Download 79 pages 15.11 Kb
Page 25
Image 25

GE863-QUADGE863-PY1vv0300715 Rev. 1 - 19/09/06

The signals of the GE863-QUAD/PY serial port are:

RS232

Signal

GE863-

Name

Usage

Pin

 

QUAD/PY

 

 

Number

 

Pad Number

 

 

1

DCD -

42

Data Carrier Detect

Output from the GE863-QUAD/PY that

 

dcd_uar

 

 

indicates the carrier presence

 

t

 

 

 

2

RXD -

38

Transmit line *see Note

Output transmit line of GE863-QUAD/PY

 

tx_uart

 

 

UART

3

TXD -

37

Receive line *see Note

Input receive of the GE863-QUAD/PY

 

rx_uart

 

 

UART

4

DTR -

39

Data Terminal

Input to the GE863-QUAD/PY that

 

dtr_uart

 

Ready

controls the DTE READY condition

5

GND

8-17-28-36-

Ground

ground

 

 

45-48-50-56

 

 

6

DSR -

43

Data Set Ready

Output from the GE863-QUAD/PY that

 

dsr_uart

 

 

indicates the module is ready

7

RTS -

40

Request to Send

Input to the GE863-QUAD/PY that

 

rts_uart

 

 

controls the Hardware flow control

8

CTS -

41

Clear to Send

Output from the GE863-QUAD/PY that

 

cts_uart

 

 

controls the Hardware flow control

9

RI -

44

Ring Indicator

Output from the GE863-QUAD/PY that

 

ri_uart

 

 

indicates the incoming call condition

NOTE: According to V.24, RX/TX signal names are referred to the application side,

therefore on the GE863-QUAD/PY side these signal are on the opposite direction: TXD on the application side will be connected to the receive line (here named TXD/ rx_uart ) of the GE863-QUAD/PY serial port and viceversa for RX.

TIP: For a minimum implementation, only the TXD and RXD lines can be connected, the other lines can be left open provided a software flow control is implemented.

The signals in the UART connector on the EVK are:

DCD

RXD

TXD

DTR

GND

DSR

RTS

CTS

RI

GND

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Right reserved