Telit Wireless Solutions GE863-PY, GE863-QUAD manual Moisture Sensibility

Models: GE863-QUAD GE863-PY

1 79
Download 79 pages 15.11 Kb
Page 76
Image 76

GE863-QUAD

GE863-PY

1vv0300715 Rev. 1 - 19/09/06

13.2.8Moisture Sensibility

The level of moisture sensibility of Telit GE863-QUAD / PY modules is “3”, according with standard IPC/JEDEC J-STD-020, take care of all the relative requirements for using this kind of components.

Moreover, the customer has to take care of the following conditions:

a)The shelf life of GE863 inside of the dry bag shall be 12 month from the bag seal date, when stored in a non-condensing atmospheric environment of <40°C / 90% RH

b)Environmental condition during the production: ≤ 30°C / 60% RH according to IPC/JEDEC J-STD- 033A paragraph 5

c)The maximum time between the opening of the sealed bag and the reflow process shall be 168 hours if the condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected

d)A baking is required if conditions b) or c) are not respected

e)A baking is required if the humidity indicator inside the bag indicates 10% RH or more

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Right reserved