SWRA004A

TRF1500 Control State

The TRF1500 operates in 18 different states: The control code and active circuits are given in Table 2.

Table 2. Control State and the Corresponding Active Circuits

Control Code

Active Circuits

(HI/LO, SYN ON, RX ON, TX ON, STRONG SIGNAL, X2)

 

000000

Sleep Mode

 

010000

Low-Band LO Input Buffer On

LB LO Buffer

011000

Low-Band Receive Normal

LB LO Buffer, LB LNA, LB Mixer

011010

Low-Band Receive Strong Signal

LB LO Buffer, LB Mixer

010100

Low-Band Transmit Mixer

LB LO Buffer, LB TX Mixer

 

 

 

011100

Low-Band Receive and Transmit Mixer

LB LO Buffer, LB LNA (On High), LB Mixer, LB TX

 

 

Mixer

011110

Low-Band Transmit Mixer

LB LO Buffer, LB LNA (On High), LB Mixer

 

 

 

010001

Doubler On

LB LO Buffer, Frequency Doubler, HB LO Buffer

011001

Low-Band Receive Normal, Doubler On

LB LO Buffer, LB LNA, LB Mixer, Frequency

 

 

Doubler

011011

Low-Band Receive Strong Signal, Doubler

LB LO Buffer, LB Mixer, Frequency Doubler

 

On

 

011111

Low-Band Transmit, Doubler On

LB LO Buffer, LB LNA (On High), LB Mixer, LB TX

 

 

Mixer

111011

High-Band Receive Strong Signal, Doubler

HB LO Buffer, HB Mixer, Frequency Doubler

 

On

 

110000

High-Band LO Input Buffer On

HB LO Buffer

111000

High-Band Receive Normal

HB LO Buffer, HB LNA, HB Mixer

111010

High-Band Receive Strong Signal

HB LO Buffer, HB Mixer

 

 

 

111001

High-Band Receive Frequency, Doubler On

LB LO Buffer, HB LO Buffer, HB LNA, HB Mixer,

 

 

Frequency Doubler

110100

High-Band Transmit Normal

HB LO Buffer, HB TX Mixer

 

 

 

110101

High-Band Transmit Frequency, Doubler

HB LO Buffer, HB TX Mixer, Frequency Doubler,

 

On

LB LO Buffer

 

 

 

TRF1500 Integrated Dual-Band RF Receiver User’s Guide

17

Page 16
Image 16
Texas Instruments manual TRF1500 Control State, Control State and the Corresponding Active Circuits