SWRA004A

1)Set the TX source frequency and input power (see Table 5). Connect the TX source to the EVM TX input port, J30.

2)Set the spectrum analyzer to measure at the TX frequency (see Table 5).

3)Connect the LO In Port, J12, to the spectrum analyzer.

4)Measure the TX leakage power.

Low-Band Transmit Mixer: 1dB Input Compression Point

Control state: 010100

SEE APPENDIX A: TEST BENCH SETUPS

Test setup Figure 20

The 1 dB input compression point is the TX RF input power at which the gain compresses 1 dB. Gain compression is when an increase in Pin causes no further increase in the output power (Pout). The measurement is performed using two RF sources and a spectrum analyzer.

1)Set the TX RF source frequency (see Table 5) and the input power (Pin) to -35 dBm. Connect the RF source to the EVM RF input port, J30.

2)Set the LO source frequency and input power (see Table 5). Connect the LO source to the EVM LO input port, J12.

3)Set the spectrum analyzer to measure the output power at the IF frequency.

4)Connect The EVM TX IF output port, J31, to the spectrum analyzer.

5)Measure the output power (Pout) at the IF frequency

6)To determine the 1 dB compression point, the TX RF Pin is increased in steps of 1 dBm until the gain compresses by 1 dB. Repeat step 4 and 5 until the gain compresses by 1dB.

7)Calculate Gain as:

Gain = Pout - Pin

RF Pin

Pout

Gain

-35

-16

19

-34

-15

19

-33

-14

19

-32

-13

19

56

 

TRF1500 Integrated Dual-Band RF Receiver User’s Guide

Page 55
Image 55
Texas Instruments TRF1500 manual Low-Band Transmit Mixer 1dB Input Compression Point