Thermador PCG48, PCG36, PCG30 installation manual 12” 305 mm ½” 12.7 mm Side flange

Models: PCG30 PCG48 PCG36

1 50
Download 50 pages 10.82 Kb
Page 10
Image 10
12”

12”

(305 mm)

½”

(12.7 mm)

Side flange

253/8

(645 mm)

Low Back

(purchased separately)

* Low Back required when there is less than

12” (305 mm) horizontal clearance from

back of cooktop to combustible material.

With more than 12” (305 mm) of clearance,

the Flush Island Trim may be used.

Manual background 9¼” (235 mm) TO CENTERLINE

OF GAS INLET

23 5/16

(592 mm)

Cabinet face for installation with projecting control panel. Manual background

Cabinet face for installation with flush control panel.

75/8

Manual background (194 mm)

1¼”

(32 mm)

Note: Unit is shown with Low Back guard (purchased separately).

Figure 5: Side View of Rangetop

11/16(18 mm) Notch Depth

Manual background 9/16(14 mm)

Front projects outward 9/16" (14 mm) as shown from standard 24"-deep base.

Figure 6: Projecting from Cabinet Front

1¼” (32 mm) Notch Depth

Front flush with cabinets; minimum of 249/16(624 mm) cabinet depth required.

Figure 7: Flush to Cabinet Front

English 8

Page 10
Image 10
Thermador PCG48, PCG36, PCG30 installation manual 12” 305 mm ½” 12.7 mm Side flange