2 STAGE FIRING RATES

Riello 2-stage burner specifications and applications:

MODEL

OL6 2-STAGE

PART

 

MTG. PLATE PART NO.

11700

 

 

MTG. PLATE GASKET

330212

PART NO.

 

**NOZZLE SIZE

.70x45° W / .50x45° W*

 

 

NOZZLE PART NO.

380702 / 380724*

 

 

OIL PUMP PRESSURE

130 LOW

170 HIGH

 

BURNER

G5D

 

 

BURNER PART NO.

380529

 

 

Table 8: Riello burner application

THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S” FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80°H”.

*Optional equipment not shipped with burner.

**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.

For more specific burner information, specifications or service information, reference the training manual enclosed with each Riello burner or contact:

Riello Corporation of America,

5 Pond Park Road Hingham, Massachusetts 02043

Phone: (617) 749-8292

2 STAGE FIRING RATES

CAPACITY

FIRING

NOZZLE SIZE

INPUT RATE*

EFFECTIVE**

 

RATE

Riello

(BTU/HR)

HEATING

 

 

 

 

CAPACITY

HIGH CAPACITY

HIGH FIRE

.70 X 45° W

106,250/170psi

90,000

LOW FIRE

85,000/130psi

74,000

 

 

LOW CAPACITY

HIGH FIRE

.50 X 45° W

85,000/170psi

74,000

LOW FIRE

70,000/130psi

60,000

 

 

Table 9: Riello 2-stage firing rates

*Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.

**Based on thermal efficiency of 84%-85%.

19

Page 22
Image 22
Thermo Products OL6RX072DV5(R) Stage Firing Rates, Capacity, Nozzle Size, Input Rate, Effective, Riello, Btu/Hr, Heating