Thermo Products OL6RA072D48(B/R) Low Capacity, High Capacity, = Recommended heating speed setting

Models: OL6FX072DV5(R) OL6RX072DV5(R) OL6RA072DV5(B/R) OL6FA072D48(B/R) OL6RA072D48(B/R) OL6FA072DV5(B/R)

1 75
Download 75 pages 52.42 Kb
Page 31
Image 31
Heating Speed Set-ups ( 2 – Stage )

Heating Speed Set-ups ( 2 – Stage )

OL6*X072DV5

 

 

 

 

 

LOW CAPACITY

 

 

HIGH CAPACITY

 

FAN

BTUH

 

LOW FIRE

 

 

HI FIRE

 

 

LOW FIRE

 

 

HI FIRE

 

CONTROL

60,000

 

72,000

 

 

72,000

 

90,000

 

 

 

 

 

 

 

 

 

SW 1

HEATING

 

APPROX.

 

 

APPROX.

 

 

APPROX.

 

 

APPROX.

 

SWITCH

 

CFM/RISE (ºF)

 

 

CFM/RISE (ºF)

 

 

CFM/RISE (ºF)

 

 

CFM/RISE (ºF)

 

CFM

 

 

 

 

 

 

 

 

SETTINGS

 

AMPS/WATTS

 

 

AMPS/WATTS

 

 

AMPS/WATTS

 

 

AMPS/WATTS

 

 

 

 

 

 

 

 

 

 

3

– OFF

 

604 / 91º

 

755 / 87º

 

 

604 / 109º

 

755 / 109º

 

 

2

– OFF

755

 

 

 

 

 

 

0.8/80

 

1.2/107

 

 

0.8/80

 

1.2/107

 

 

1

– OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– OFF

 

 

661 / 83º

 

 

826 / 80º

 

 

661 / 100º

 

826 / 100º

 

 

2

– OFF

826

 

 

 

 

 

 

 

 

 

0.9/83

 

 

1.4/120

 

 

0.9/83

 

1.4/120

 

 

1

– ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– OFF

 

 

718 / 70º

 

 

898 / 74º

 

 

718 / 92º

 

898 / 92º

 

 

2

– ON

898

 

 

 

 

 

 

 

 

 

0.95/96

 

 

1.5/139

 

 

0.95/96

 

1.5/139

 

 

1

– OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– OFF

 

 

786 / 64º

 

 

983 / 67º

 

 

 

786 / 84º

 

 

983 / 84º

 

 

2

– ON

983

 

 

 

 

 

 

 

 

 

 

 

1.1/117

 

 

1.8/169

 

 

 

1.1/117

 

 

1.8/169

 

 

1

– ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– ON

 

 

854 / 59º

 

 

1068 / 62º

 

 

 

854 /

 

 

1068 / 77º

 

 

2

– OFF

1068

 

 

 

 

 

 

 

 

 

 

 

1.3/131

 

 

2.0/190

 

 

 

77º1.3/131

 

 

2.0/190

 

 

1

– OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– ON

 

 

934 / 54º

 

 

1168 / 57º

 

 

 

934 / 71º

 

 

1168 / 71º

 

 

2

– OFF

1168

 

 

 

 

 

 

 

 

 

 

 

1.5/139

 

 

2.4/222

 

 

 

1.5/139

 

 

2.4/222

 

 

1

– ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FACTORY

3 – ON

 

1025 / 50º

 

1282 / 52º

 

 

 

1025 / 64º

 

 

1282 / 64º

 

SW1 SWITCH

2 – ON

1282

 

 

 

 

 

 

 

2.0/190

 

2.9/277

 

 

 

2.0/190

 

 

2.9/277

 

SETTINGS

1

– OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

– ON

 

1139 / 48º

 

1397/ 46º

 

 

 

1139 / 58º

 

 

1397 / 60º

 

 

2

– ON

1397

 

 

 

 

 

 

 

 

2.4/222

 

4.0/378

 

 

 

2.4/222

 

 

4.0/378

 

 

1

– ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW CAPACITYHIGH CAPACITY = Recommended heating speed setting = Recommended heating speed setting

Figure 18-2: ECM 2-stage blower motor speed chart

28

Page 31
Image 31
Thermo Products OL6RA072D48(B/R), OL6FA072DV5(B/R) Low Capacity, High Capacity, = Recommended heating speed setting