Heating Speed Set-ups

Heating Speed Set-ups

OL6*A072DV5

 

 

 

 

 

 

 

 

Furnace Motor Current

 

 

 

 

 

 

 

 

 

Draw (Amps/ / Watts) vs.

 

 

 

 

 

 

 

 

 

External Static Pressure (in W.C.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Fire

Med Fire

High Fire

 

 

 

 

 

 

BTUH

60,000

72,000

90,000

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

SW 1

 

 

 

Aprox. Rise

Aprox. Rise

 

 

 

 

 

Switch

Heating

Aprox. Rise

 

 

 

 

 

Settings

CFM

(F0 )

 

(F0 )

 

(F0 )

 

0.2

0.4

 

0.6

 

3-OFF

755

73o

 

 

 

 

1.2/107

1.6/151

 

2.1/208

 

2-OFF

 

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-OFF

826

66

o

80

o

 

 

1.3/120

1.9/173

 

2.4/232

 

2-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

3-OFF

898

61

o

74

o

 

 

1.5/139

2.1/199

 

2.6/246

 

2-ON

 

 

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

Factory

3-OFF

 

 

 

 

 

 

 

 

 

 

 

SW1

983

56o

67o

84 o

1.8/169

2.4/234

 

3/290

Switch

2-ON

 

 

 

 

 

 

 

 

 

 

 

Settings

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

1068

 

 

62

o

77

o

2.0/190

2.7/249

 

3.4/332

 

2-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

1168

 

 

57

o

71

o

2.4/222

3.1/303

 

4.0/392

 

2-OFF

 

 

 

 

 

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

1282

 

 

 

 

64

o

2.8/277

3.8/377

 

4.5/452

 

2-ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

1397

 

 

 

 

60

o

4.0/378

4.7/474

 

5.6/552

 

2-ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

 

= Recommended Heating Speed Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 18-1: ECM blower motor speed chart

27

Page 30
Image 30
Thermo Products OL6FA072DV5(B/R) Heating Speed Set-ups, OL6*A072DV5, Furnace Motor Current, Draw Amps/ / Watts vs