Thermo Products OL6FA072D48(B/R) Cooling Speed Set-ups OL6**072DV5, Furnace Motor Current

Models: OL6FX072DV5(R) OL6RX072DV5(R) OL6RA072DV5(B/R) OL6FA072D48(B/R) OL6RA072D48(B/R) OL6FA072DV5(B/R)

1 75
Download 75 pages 52.42 Kb
Page 32
Image 32

Cooling Speed Set-ups

OL6**072DV5

 

 

 

 

 

Furnace Motor Current

 

 

 

 

 

Draw (Amps / Watts) vs.

 

 

 

 

 

External Static Pressure (in W.C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Flow

 

 

 

 

Fan

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

SW 1

 

 

 

 

 

 

 

 

Switch

Clg.

 

 

 

 

 

 

 

Settings

Tonnage

Cool

 

Continuous

0.2

0.5

 

 

6-OFF

2

799

 

500

1.3/115

2.0/186

 

 

5-OFF

 

 

 

4-OFF

 

 

 

 

 

 

 

 

6-OFF

 

 

 

 

 

 

 

 

5-OFF

2.5

1017

 

508

1.9/174

2.7/254

 

 

4-ON

 

 

 

 

 

 

 

 

6-OFF

 

 

 

 

 

 

 

 

5-ON

3

1210

 

605

2.5/239

3.8/360

 

 

4-OFF

 

 

 

 

 

 

 

 

6-OFF

 

 

 

 

 

 

 

 

5-ON

3.5

1404

 

702

3.0/269

5.0/492

 

 

4-ON

 

 

 

 

 

 

 

Factory SW1

6-ON

 

 

 

 

 

 

 

Switch

5-OFF

4

1622

 

799

5.0/479

6.5/640

 

Settings

4-OFF

 

 

 

 

 

 

 

 

6-ON

 

 

 

 

 

 

 

 

5-OFF

-

1817

 

897

6.3/612

7.9/799

 

 

4-ON

 

 

 

 

 

 

 

 

6-ON

 

 

 

 

 

 

 

 

5-ON

5

2010

 

993

8.5/871

10.2/1004

 

 

4-OFF

 

 

 

 

 

 

 

NOTE: All information is approximate. Results will vary by installation.

Figure 18-3: Cooling blower motor speed chart

29

Page 32
Image 32
Thermo Products OL6FA072D48(B/R) Cooling Speed Set-ups OL6**072DV5, Furnace Motor Current, Draw Amps / Watts vs