MIDCO RE32 BURNER ADJUSTMENT
1.1X TR TEMPERATURE RISE = HEATING CFM EXAMPLES
Page 35
Image 35
All installations and services must be performed by qualified service personnel.
33
Page 34
Page 36
Page 35
Image 35
Page 34
Page 36
Contents
MG-807C
MODELS PGT5-100, PGT11-125, PGT16-160
PGL20-180, PGL33-250, PGL37-312,& PGL39-400
SECTION
TABLE OF CONTENTS
Page
CAUTION When installing the burner, it should be noted that the loose fill insulation and fiber chambers are made with ceramic fibers. Currently, there are no known chronic health effects in humans associated with long term exposure to ceramic fibers. The International Agency for Research on Cancer IARC based on its review of studies that injected ceramic fiber into the abdomens of hamsters and rats have classified fibrous glass wool, mineral wool both rock wool and slag wool and ceramic fiber as group 2B carcinogens. A group 2B agent is considered by IARC to have the possibility of being carcinogenic to humans. IARC has also classified these fibrous materials as group 2A carcinogens when they have undergone long term exposure to temperatures greater than 18000F. A group 2A agent is considered to have the probability of being carcinogenic to humans. For these reasons, we suggest the use of a 3M 9900, 3M 8710 or equivalent mask when working with any ceramic fiber products. For further information, contact the Manager of Customer Service for Rex Roto Corporation at
B. CONSTRUCTION MATERIALS a. COMBUSTIBLE MATERIAL
II. GENERAL INSTALLATION
I. GENERAL INSTRUCTIONS
A. CODES AND CLEARANCES
MODEL NO
D. VENTING
MAKE-UPAIR
Page
F. CONDENSING IN THE CHIMNEY
E. VENT DAMPERS
H. GENERAL GAS PIPING
I. INSTALLATION OF NATURAL GAS PIPING
TYPICAL PIPING FOR TWO STAGE REGULATION
BLACK PIPE SIZE FOR NATURAL GAS
TOP VIEW BURNER INSERTION ILLUSTRATION PGL
K. BURNER INSTALLATION
COPPER TUBING SIZE FOR LIQUIFIED PETROLEUM GASES
SIDE VIEW BURNER INSERTION ILLUSTRATION PGT
TWO PIECE MOUNTING PLATE
HORIZONTAL FURNACE POSITIONS
MIDCO RE32 BURNER ADJUSTMENT
No. Turns Closed
Furnace Model
Orifice Size
Manifold Gas Pressure
L. REQUIREMENTS AND SIZING OF DUCT WORK
EXAMPLE Heating output of furnace is 100,000 x 1.4 ÷ 100 = 1400 CFM. Air conditioning installed is 4 tons
A.110,000 BTU OUTPUT
1.1X TR TEMPERATURE RISE = HEATING CFM EXAMPLES
DUCT WORK/AIR CONDITIONING
1. HEATING CFM BTUS OUTPUT OF FURNACE
A. PGT HORIZONTAL UNITS B. PGL LOWBOY
M. FILTERS
FAN & LIMIT LOCATION FOR HORIZONTALS
N. FAN AND LIMIT POSITION AND LOCATION
LOCATION FOR LOWBOYS & HORIZONTALS
WITHOUT AIR CONDITIONING
O. WIRING
LATEST EDITION
Page
Page
Page
Page
Wiring
B. BURNER COMBUSTION
C. ADJUSTMENT OF BTU INPUT RATE
II.STARTING THE UNIT A. INITIAL START UP
OPERATING INSTRUCTIONS
Seconds for one revolution
FURNACE
ORIFICE CHART
D. FURNACE CHECKOUT PROCEDURE
IV. INSTALLERS INSTRUCTIONS TO USER
B. CLEANING HEAT EXCHANGER
V. DEALER MAINTENANCE A. ELECTRICAL
VI. TROUBLESHOOTING
VII. REPLACEMENT PARTS
Page