Manuals
/
Brands
/
Lawn and Garden
/
Telescope
/
Topcon
/
Lawn and Garden
/
Telescope
Topcon
GTS-821A, GTS-822A, GTS-823A, GTS-825A, GTS-822A, GTS-823A, GTS-825A instruction manual
1
1
144
144
Download
144 pages, 3.58 Mb
INSTRUCTION MANUAL
AUTO TRACKING TOTAL ST
ATION
GTS-820A
SERIES
GTS-821A
GTS-822A
GTS-823A
GTS-825A
Contents
Main
Page
1
FOREWORD
General Handling Precautions
Page
Display for Safe Use
Safety Cautions
User
Exceptions from Responsibility
CAUTION
Laser Safety
Labels
CAUTION
Contents
1 NOMENCLATURE AND FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2 PREPARATION FOR MEASUREMENT . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION . . . . . . . . . . 3-1
4 STANDARD MEASUREMENT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
6 MEMORY MANAGE MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
7 COMMUNICATION MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
8 PARAMETERS SETTING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
9 CHECK AND ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
12 CORRECTION FOR REFRACTION AND EARTH CURVA TURE . . . 12-1
Page
Standard Set Composition
1-1
1 NOMENCLATURE AND FUNCTIONS
1.1 Nomenclature
1-2
1-3
1.2 Display
1.3 Operating Key
1-4
*
1.4 Function Key (Soft Key)
V : 8755'45"5 HR: 18044'12"5 SD HD NEZ 0SET HOLD
1-6
1-7
1.5 Star key (*key) mode
Screen 3
2003-10-10 14:30:40
Screen 1
Screen 2
1-8
X:------------- Y:-------------
1-9
512KB
1-10
Meaning of Tracking Indicator ON or Flashing
1.6 Auto Power Off
1.7 Data Output
1.8 Rotating Method
1-12
1.9 Using together with RC-2II Remote Control System
Turn-round function
1-13
1.10 Using connecting with Personal Computer (PC)
2-1
2 PREPARATION FOR MEASUREMENT
2.1 Power Connection
(unnecessary if on-board Ni-MH battery BT-56Q is used)
2-2
2.2 Setting Instrument Up For Measurement
Reference: Leveling and Centering t he Instrument
2-3
2.3 Power Switch Key ON
2-4
2.4 Battery Level Indicator
2-5
2.5 Main Menu Icons
STANDARD MEASUREMENT MODES
PROGRAM MODES ( APPLICATION MEASUREMENT)
COMMUNICATION MODES
ADJUSTMENT MODES
2.6 Vertical and Horizontal Angle Tilt Correction
X: Y:
2-7
2.7 Compensation of Systematic Error of Ins tru m ent
1
2
3
4
2.8 Resume Mode ON/OFF
2.9 How to Enter Numerals and Alphabet Letters
1
2
3
2.10 Memory Card
How to extract a memory card
How to insert a memor y card
2-10
2.11 Inclination of Prism and Measuring Error
Prism constant value : 30mm
Prism constant value : 0mm
2-11
(Example)
Angle error =
Angleerror range Measuring dis cetan
-------------------------------------------- ----------
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION
3.1 Automatic Tracking
WARNING
CAUTION
1
3-2
4
Searching status
status Waiting status
Automatic tracking Normal mode
3.2 Automatic Collimation
1
2Press the star [*] key. [*] 3
4
3.3 Range of Laser for Auto-tracking and Auto-collimating
3-5
3.4 Setting Parameters for Auto -Tracking
3.4.1 Setting Items
1) Search Patterns
2) Search Range
3-6
3) Wait Time
4) Tracking Speed
5) Reflector type
6) Prediction operating time
Page
4-1
4 STANDARD MEASUREMENT MODE
4.1 Angle Measurement
4.1.1 Measuring Horizontal Angle Right and Vertical Angle
1
2
4-2
4.1.2 Switching Horizontal Angle Right/Left
4.1.3 Measuring from the Required Horizontal Angle
1) Setting by Holding the Angle
1
4-3
2) Setting a Horizontal Angle from the Keys
4.1.4 Vertical Angle Percent Grade(%) Mode
1
3
4-4
4.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Angle
<Rotating...>
1
2 3 4
4.2 Distance Measurement
4-6
4.2.4 Distance Measurement (Single/N-times Measurement)
1)Setting the number of times
2)Measuring Method
1
4-7
4-8
4.2.5 Fine / Coarse Measuring Mode
1 2
3
4-9
4.2.6 Stake Out (S-O)
Display value = Measured distance -Standard (Preset) distance
1
2 3
4.3 COORDINATE MEASUREMENT
4.3.1 Setting Coordinate Values of Occupied Point
1
3
N
4-11
4
4-12
4.3.2 Setting of the Instrument Height / Prism Height
1
3
4
4-13
4.3.3 Execution of Coordinate Measuring
1
2
3 4
4-14
4-15
4.4 DATA OUTPUT
1
2
3
Page
5-1
5 PROGRAM MODES
5-2
5.1 Setting a Direction Angle for Backsight Orientation
(Entering the in strument and backs ight coordinate values)
1
2 3
4 5
5.2 Retaining a Coordinate (STORE- NEZ)
1 2 3
4
5-4
5
6
7
8 9 10
5.3 Remote Elevation measurement (REM)
1) With prism height (h) input (Example :h=1.5m)
1 2 3
4
5
Page
Page
5-8
5.4 Missing Line Measurement (MLM)
1 2
5-9
3
4 5
6
7
Page
5-11
5.5 Line Measurement (LINE)
1
2 3
4
5-12
5
6
7
8
Page
5-14
5.6 Offset measurement (OFFSET)
lOutputting the Measurement Data
lDistance measurement mode of the offset measurement
5-15
5.6.1 Angle Offset
3
1
5-16
4
5
6
7
A
5-18
4
5
6
7
5-19
5.6.3 Plane Offset Measurement
P
1
3
5-20
4
5
6
7
5-21
5.6.4 Column Offset Measurement
1
3
4
5-22
5
6
7
8
5.7 External Link
5.7.1 Starting compatible communication program of AP-L1A
5.7.2 Setting for the communication
(1)Setting communication course
1
5-24
(2)Setting Parameters of Cable (RS-232C)
3
4
5-25
(3)Setting Parameters of RC
Parameters
2
3
5-26
(4)Setting Parameters for Radio Modem
Parameters
2
3
5-27
5.7.3 Carrying out Communication
2
3
1
6 MEMORY MANAGE MODES
6.1 View Internal Memory and Car d Memory Status
1
2
6-2
6.2 Protect a File
6.3 Rename a File
2 3
4
2
6.4 Deleting a File
6.5 Copy a File
2
3
4
6.6 Initializing Memory
1 2 3
4
5
7-1
7 COMMUNICATION MODES
7.1 Setting of PROTOCOL
1 2
7-2
7.2 Data File In
7.3 Data File Out
1 2
3
8-1
8 PARAMETERS SETTING MODE
8.1 Parameter Setting Options
8.1.1 Parameters for Measurement and Display
8-2
8-3
8.1.2 Parameters for communication
Setting parameter for RC
Serial port Setting parameters for RS232C
8-4
8.2 Setting Parameters
8-6
8.2.2 Parameters for Communication
8.2.3 Password Option
Establishing a Password
1 2
8-7
Turning OFF the Password
Turning OFF the Password Option
2
3
8-8
Changing a Password
Changing the Password
4
1
9 CHECK AND ADJUSTMENT
9.1 Checking and Adjusting of Instrument Constant
9-2
9.2 Checking the Optical Axis
H direction confirmation (Do not move V direction).
9-3
Vertical direction confirmation (Do not move Horizontal direction).
9-4
9.3 Checking/Adjustin g the Theodolite Functions
9-5
9.3.1 Checking /Adjusting the Plate Level
9.3.2 Checking /Adjusting the Circular Level
9-6
9.3.3 Adjustment of the Vertical Cross-hair
9-7
9.3.4 Collimation of the Instrument
9-8
9.3.5 Checking / Adjusting the Optical Plummet Telescope
9-9
9.4 Adjustment of Compensation Systematic Error of Instrument
1
2 3
4
5
Page
9.5 Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrument
9-12
9.6 How to adjust the date and time
1 2
3
4
5 6
9.7 How to Set the Instrument Constant Value
1 2 3 4
5
9-14
9.8 Reference Frequency Checking Mode
1 2
3
4
9-15
9.9 Inspection and Adjustment of Optic Axis for Auto -Tracking
1
2 3
4
5
9-16
8
9
10 SETTING THE PRISM CONSTANT VALUE
11-1
11 SETTING ATMOSPHERIC CORRECTION
11.1 Calculation of Atmospheric Correction
11.2 Setting of Atmospheric Correction Value
1
2
Page
11-3
Page
Page
12-1
12 CORRECTION FOR REFRACTION AND EARTH CURVATURE
12.1 Distance Calculation Formula
13-1
13 POWER SOURCE AND CHARGING
13.1 Rechargeable Battery BT-56Q
13-2
14-1
14 DETACH/ATTACH OF TRIBRACH
15-1
15 BATTERY SYSTEM
16-1
16 PRISM SYSTEM
17-1
17 PRECAUTIONS
18-1
18 ERROR DISPLAYS
19-1
19 SPECIAL ACCESSORIES
19-2
19-3
20-1
20 SPECIFICATIONS
20-2
20-3
20-4
APPENDIX-1
APPENDIX
1 Dual Axis Compensation
APPENDIX-2
APPENDIX-3
2 Precaution when Charging or Stor i ng B a tteries
APPENDIX
APPENDIX-4
Fig.1 Recharging
Fig. 2 Discharge
Fig. 3 Storage
END USER LICENSE AGREEMENT
SOFTWARE LICENSE AGREEMENT (Embedded Products)
APPENDIX WARRANTY AND SPECIAL PROVISIONS LIMITED WARRANTY
EMC NOTICE
Page
TOPCON CORPORATION
AUTO TRACKING TOTAL STATIO
N
GTS-820A