1-5
1 NOMENCLATURE AND FUNCTIONS
1.4 Function Key (Soft Key)
The Soft Key Functions are labeled on the bottom of display. Soft Key functions are different for each
measurement.
Page Display Soft
key Function
Angle
measuring
SD F1 Slope distance measuring mode.
HD F2 Horizontal distance measuring mode.
NEZ F3 Coordinate distance measuring mode.
0SET F4 Set horizontal angle to 0°00'00".
HOLD F5 Horizontal angle hold.
TURN F1 Turns the instrument to required angle automatically.
HSET F2 Preset a horizontal angle.
R/L F 3 Changes horizontal angle right or left.
V/% F4 Changes the display to vertical angle or percent of grade.
TILT F5 Sets the tilt function, ON/OFF.
If ON, the display shows tilt correction value.
Horizontal distance measuring Coordinate measu ring
Angle measuring Slope distance measuring
TURN HT MEAN P2
REC SO MEAN P2
TURN SO MEAN m/ft P2
TURN HSET R/L V/% TILT P2
Soft keys
V : 87°55'45"5HR: 180°44'12"5
SD HD NEZ 0SET HOLD P1
[F1] [F2] [F3] [F4] [F5] [F6]
V : 87°55'45"5
HR: 180°44'12"5
SD HD NEZ 0SET HOLD P1
V : 90 10'20"5
HR: 120 30'40"5 PSM 0.0
HD: PPM 0.0
VD: (m) F.R
MEAS MODE VH SD NEZ P1
V : 90°10'20"5
HR: 120°30'40"5 PSM 0.0
SD: PPM 0.0
(m) F.R
MEAS MODE VH HD NEZ P1
N : 12345.6789
E : -12345.6789 PSM 0.0
Z : 10.1234 PPM 0.0
(m) F.R
MEAS MODE VH SD HD P1