4 STANDARD MEASUREMENT MODE

4.2.4 Distance Measurement (Single/N-times Measurement)

When presetting the number of times, the instrument measures the distance as the setting times and the average distance will be displayed.

When presetting the number of times as 1, it does not display the average distance, because of single measurement. It has been set at single measurement at factory.

1)Setting the number of times Confirm the angle measurement mode.

 

Operating procedure

Operation

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Press [F1](SD) or [F2](HD) key.

 

 

 

 

 

 

 

 

 

 

 

 

V : 90°10'20"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HR: 120°30'40"

 

 

 

 

 

 

 

SD

HD

NEZ

0SET

HOLD P1

 

 

 

[F2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V :

 

°

 

 

 

 

 

 

 

 

 

90 10'20"

 

 

 

 

 

 

 

HR: 120°30'40"

PSM

0.0

 

 

 

 

 

HD:

 

 

 

 

PPM

0.0

 

 

 

 

 

VD:

 

 

 

 

(m)

F.R

 

2

Press [F6]() key to get the function page as

[F6]

 

MEAS

MODE

VH

SD

NEZ

P1

 

 

REC

SO

MEAN

m/ft

P2

 

 

2.

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press [F3](MEAN) key.

[F3]

 

 

 

 

 

 

 

 

 

 

Average times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N:0

 

 

 

 

 

 

 

 

 

 

 

EXIT

 

 

 

 

 

BS

 

4

Input the setting the number of times, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[F4][ENT]

 

V :

90°10'20"

 

 

 

 

press [ENT] key. *1)

 

 

 

 

 

 

 

HR: 120°30'40"

PSM

0.0

 

 

[Example] 4 times

 

 

 

 

 

 

HD:

 

 

 

<

PPM

0.0

 

 

N-times measurement starts.

 

 

 

 

 

 

 

 

 

VD:

 

 

 

 

(m) *F.N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC

SO

 

MEAN m/ft

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)Measuring Method

 

 

 

 

 

 

 

 

 

 

 

Confirm the angle measurement mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating procedure

Operation

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Collimate the center of the prism.

 

 

 

 

 

 

 

 

 

 

Collimate

 

V :

90°10'20"

 

 

 

 

 

 

 

 

 

 

 

 

 

HR: 120°30'40"

 

 

 

 

 

 

 

SD

HD

NEZ

0SET

HOLD P1

 

2

Select the measurement mode by pressing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[F2]

 

V :

 

°

 

 

 

 

 

 

[F1](SD) or [F2](HD) key.

 

90 10'20"

 

 

 

 

 

 

HR: 120°30'40"

PSM

0.0

 

 

Example: Horizontal distance

 

 

HD:

 

 

 

 

PPM

0.0

 

 

N-times measurement starts.

 

 

 

 

 

 

 

 

 

 

VD:

 

 

 

 

(m)

F.N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEAS

MODE

VH

SD

NEZ

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-6

Page 48
Image 48
Topcon GTS-825A, GTS-822A, GTS-823A instruction manual Distance Measurement Single/N-times Measurement, 2Measuring Method

GTS-822A, GTS-825A, GTS-821A, GTS-822A, GTS-823A, GTS-825A, GTS-823A specifications

Topcon's GTS series of total stations, including the GTS-821A, GTS-822A, GTS-823A, and GTS-825A, are known for their robust features and exceptional precision, catering to the needs of surveying and construction professionals. These instruments blend advanced technology with user-friendly interfaces to enhance productivity in the field.

The GTS-821A model is designed for reliability and accuracy. It offers a measurement range of up to 1,000 meters and delivers precision within ±2 millimeters, making it ideal for jobs requiring fine detail. Key features include a high-speed angle measurement system and a dual-axis compensator that ensures accuracy on uneven terrain.

In contrast, the GTS-822A model takes performance a step further by incorporating advanced optical technologies. It includes a high-performance EDM (Electronic Distance Measurement) that allows for faster measurements with a range extending up to 2,000 meters. This model also integrates a clear display and simple user interface, facilitating easier operation for users of all skill levels.

The GTS-823A represents a perfect blend of portability and advanced functionality. It is lightweight, making it easy to transport between job sites. This model incorporates GPS capabilities, allowing seamless integration with GNSS systems for enhanced positioning accuracy. Its onboard software supports various surveying methods, making it versatile for different applications.

The GTS-825A stands out for its advanced features tailored for high-precision tasks. This model supports wireless communication, enabling real-time data transfer to smartphones and tablets, which enhances collaboration in fieldworks. With an impressive measurement capability, it extends the measurement range and precision, meeting the demands of large-scale projects.

All models in this series share a durable design reputation, ensuring they withstand harsh environmental conditions. Their user-friendly interfaces are complemented by robust software support, providing surveying professionals with the tools they need to optimize their workflows.

In summary, Topcon’s GTS series, including the GTS-821A, GTS-822A, GTS-823A, and GTS-825A, represent the cutting edge of surveying technology, boasting features like extended measurement ranges, high precision, advanced EDM, and GPS integration. These instruments not only enhance productivity but also ensure that professionals can achieve their surveying goals efficiently and effectively. Whether for routine land surveys or complex construction projects, the Topcon GTS series delivers exceptional performance and reliability.