4-6
4 STANDARD MEASUREMENT MODE
4.2.4 Distance Measurement (Single/N-times Measurement)
When presetting the number of times, the instrument measures the distance as the setting times and
the average distan ce will be displayed.
When presetting the number of times as 1, it does not display the average distance, because of single
measurement. It has been set at single measurement at factory.

1)Setting the number of times

Confirm the angle measurement mode.

2)Measuring Method

Confirm the angle measurement mode.
Operating proced ure Operation Display
1Press [F1](SD) or [F2](HD) key.
2Press [F6](
) key to get the function page as
2.
[F2]
[F6]
3Press [F3](MEAN) key. [F3]
4Input the setting the numb er of times, and
press [ENT] key. *1)
[Example] 4 times
N-times measurement starts.
[F4][ENT]
Operating proced ure Operation Display
1Collimate the center of the prism. Collimate
2Select the measurement mode by pressi ng
[F1](SD) or [F2](HD) key.
Example: Horizo nt al distance
N-times measurement starts.
[F2]
V : 90°10'20"
HR: 120°30'40"
SD HD NEZ 0SET HOLD P1
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: PPM 0.0
VD: (m) F.R
MEAS MODE VH SD NEZ P1
REC SO MEAN m/ft P2
Average times
N:0
EXIT BS
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: < PPM 0.0
VD: (m) *F.N
REC SO MEAN m/ft P2
V : 90°10'20"
HR: 120°30'40"
SD HD NEZ 0SET HOLD P1
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: PPM 0.0
VD: (m) F.N
MEAS MODE VH SD NEZ P1