E6581268

3.4.5.3. Instance 100/150 – Toshiba Specific (f894 = 2)

 

 

 

 

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

 

Bit 2

Bit 1

 

Bit 0

0

DC braking

ACC1/

PI off

THR2

Preset

 

Preset

Preset

 

Preset

ACC2

Speed4

 

Speed3

Speed2

 

Speed1

 

 

 

 

 

 

1

Command

Frequency

Reset trip

Emergency

Free run (ST)

 

Run/stop

Fw/

 

Jog

 

link *

link *

 

stop

 

 

 

Reverse

 

 

2

 

 

Drive Reference Speed Hz (Low byte) **

 

 

 

3

 

 

Drive Reference Speed Hz (High byte) **

 

 

 

 

 

 

Fig. 5 Output Instance 100 Layout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

 

Bit 2

Bit 1

 

Bit 0

0

DC braking

ACC2

PI

tHr2

-

 

ALARM

EMG

 

FL

(VF2+tH2)

 

(fc91)

 

 

 

 

 

 

 

 

 

 

 

 

READY

READY

Emergency

Free run

 

Run/

Fw/

 

 

1

-

without

 

 

Jog

with ST/ RUN

stop

(ST)

 

Stop

Reverse

 

 

 

ST/RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Drive Actual Speed Hz (Low byte)

 

 

 

3

 

 

Drive Actual Speed Hz (High byte)

 

 

 

Fig. 6 Input Instance 150 Layout

*Bit 14 and 15 of the instance 100 byte 0 are defined as follows.

Bit 15 (Command link)

When “0” is set, the other command does not work except bit 12 and 13,

 

Run/Stop is according to setup of the parameter cmod.

Bit 14 (Frequency link)

When “1” is set, bytes 2 and 3 are enabled. When “0” is set, Drive Reference

 

Speed is according to setup of the parameter fmod.

**Drive Reference Speed is set up by 0.01Hz unit and the hexadecimal number.

For example, when "Frequency reference" is set up to 60Hz, since the minimum unit is 0.01Hz, 60 / 0.01 = 6000 = 0x1770 (Hex.)