E6581268

Examples of Instance 101/151

Access the inverter parameter is enabled using byte 4 to 6 of this Instance.

Set the communication number of the parameter to byte 4, 5 (Index), and the value to byte 6, 7 (Data).

In case of the monitor parameter “FE**”, the value becomes "communication number - 0xF000 (same as bit12 - 15 set to 0)".

Read the parameter cmod (Command mode selection, communication number is 0003).

Instance

Byte

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

Hex.

Output Instance 101

5, 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0x0003

7, 6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

Input Instance 151

5, 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0x0003

(cmod is set 0.)

7, 6

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

Read the parameter f260 (Jogging frequency).

Instance

Byte

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

Hex.

Output Instance 101

5, 4

0

0

0

0

0

0

1

0

0

1

1

0

0

0

0

0

0x0260

7, 6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

Input Instance 151

5, 4

0

0

0

0

0

0

1

0

0

1

1

0

0

0

0

0

0x0260

(f268 is set 5.0Hz.)

7, 6

0

0

0

0

0

0

0

1

1

1

1

1

0

1

0

0

0x01F4

Read the parameter fe04 (Voltage of DC bus).

Instance

Byte

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

Hex.

Output Instance 101

5, 4

0

0

0

0

1

1

1

0

0

0

0

0

0

1

0

0

0x0E04

7, 6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

Input Instance 151

5, 4

0

0

0

0

1

1

1

0

0

0

0

0

0

1

0

0

0x0E04

(fe04 is 97.60%.)

7, 6

0

0

1

0

0

1

1

0

0

0

1

0

0

0

0

0

0x2620

Write “60 (Hz)” to the parameter sr1 (Preset speed 1, communication number is 0018).

 

 

Instance

Byte

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

Hex.

Output Instance 101

5, 4

1

0

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0x8018

7, 6

0

0

0

1

0

1

1

1

0

1

1

1

0

0

0

0

0x1770

 

Input Instance 151 (OK)

5, 4

1

0

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0x8018

7, 6

0

0

0

1

0

1

1

1

0

1

1

1

0

0

0

0

0x1770

 

Input Instance 151 (NG)

5, 4

1

1

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0xC018

(Error code *)

7, 6

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0x0001

About byte 0 - 3, refer to section 3.4.5.2.

*Refer to following about the error code.

1(= BN: 00000001):: Data out of range

2(= BN: 00000010):: Bad address

- 18 -

Page 19
Image 19
Toshiba DEV001Z manual Examples of Instance 101/151