E6580772

3.1.3 Communication parameters

„F10M communication parameters

Parameter name

Title

Setting value

Details

Inverter number

f802

0 to 255

Sets inverter station address. (Note 1)

 

 

 

When using a message transmission, set the address of the

 

 

 

master station to 0 and address of the inverter station to 1 or

 

 

 

over.

Data type

f830

0, 1

Selects type of transmitting and receiving data.

selection

 

 

0: VFA7 mode

 

 

 

1:μs250 mode

Input reference

f831

0 to 16

Sets scan transmission data to be received.

setting 1

 

 

0: Without setting

Input reference

f832

 

1: Command

setting 2

 

 

2: Speed reference value

Input reference

f833

 

3: Auxiliary speed reference value

setting 3

 

 

4: Torque limit value

Input reference

f834

 

5: Positive torque limit value

setting 4

 

 

6: Negative torque limit value

Input reference

f835

 

7: Torque command value

setting 5

 

 

8: Synchronized torque bias

Input reference

f836

 

9: Tension torque bias

 

10: Load sharing gain

setting 6

 

 

 

 

11: Drooping gain

 

 

 

 

 

 

12: Speed loop proportional gain

 

 

 

13: Speed loop accumulative gain

 

 

 

14: Terminal output data

 

 

 

15: Inertia moment ratio

 

 

 

16: Expansion command

Monitor output

f841

0 to 16

Sets scan transmission data to be sent.

setting 1

 

 

0: Without setting

Monitor output

f842

 

1: Status

setting 2

 

 

2: Operation frequency

Monitor output

f843

 

3: Speed feedback value (real time)

setting 3

 

 

4: Speed feedback value (1-second filter)

Monitor output

f844

 

5: Internal torque reference value

setting 4

 

 

6: Output amperage

Monitor output

f845

 

7: Exciting amperage

setting 5

 

 

8: Torque amperage

Monitor output

f846

 

9: Overload accumulative value

 

10: Deleted torque of acceleration/deceleration torque

setting 6

 

 

 

 

11: Motor counter data

 

 

 

 

 

 

12: Error code

 

 

 

13: Input terminal data

 

 

 

14: VI input

 

 

 

15: RR input

 

 

 

16: RX input

12