3.2.2 Connection of PG

As for the pulse input signals, PGA1 and PGA2 are connected for Phase A, PGB1 and PGB2 are connected for Phase B, and PGZ1 and PGZ2 are connected for Phase Z.

(The wiring for Phase Z is done only when using Z-marker is necessary.) The polarity of the pulse input signals should be as follows:

+ side: PGA1, PGB1, PGZ1

- side: PGA2, PGB2, PGZ2

The signal which is fed back from the encoder should have the waveform of the figure below in terms of the direction of motor rotation. The encoder installation direction and signal wiring should be done accordingly.

Forward rotation or reverse rotation is judged from the feedback pulses of Phase A and Phase B (2-phase pulse that have 90 degrees of phase difference). Therefore, it should be noted that, when connections are wrong, there is possibility for abnormal rotation of the motor.

Phase A(VA)

Forward rotation

Phase B(VB)

PGA1

A

 

 

A

PGA2

A

 

 

PGB1

B

 

 

PGB2

B

 

 

Phase A(VA)

Reverse rotation

Phase B(VB)

X1 X2 X3 X4

PG

Phase differenceXn0.15T(n=1,2,3,4)

Judgement on normal and reverse rotations by the PG feedback of two phases (Phases A and B)

<When PG feedback signal is single phase>

1.For PG feedback signal, connect terminals PGA1 and PGA2.

2.The judgement on forward rotation and reverse rotation is impossible. Only the speed control mode is applicable.