EMl-31015D

NOTES:

1.In this scale, the previously set bar code format is cleared by RAM clear, and can be

switched

to

the

following

formats.

Therefore,

it is

necessary to

set the

bar code

format

again after RAM

clear.

 

 

 

 

 

 

 

 

 

 

Bar Code Format by Initialization:

 

 

 

 

 

 

 

 

0

Weighing

format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C2

C3

C4

C5

C6

PC/D

Pl

P2

P3

P4

C/D

8

By

Count

Format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C2

C3

C4

C5

0

0

0

0

C6

C/D

8

Fix

Price

Format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C2

C3

C4

C5

C6

PC/D

Pl

P2

P3

P4

 

@

RECEIPT Format (for C4-36 only)

 

 

 

 

 

 

 

 

 

0

2

 

D2

D3

D4

D5

D6

PC/D

Pl

P2

P3

P4

C/D

2.When the ENTER key is depressed, format check is executed, resulting in an error in the following cases.

0 Price check digit (PC/D) cannot be calculated.

8 Price is not set serially beginning from Pl.

0 The format does not comply with the bar code format.

3.Check digit (C/D) is set automatically to the digit-13.

4.The usable keys to set the column are as follows:

FLAG

 

El

-I

PLU#

 

i-i-l -I

UPC#

 

 

 

PC/D

 

 

 

P&E

1

1

; ;

DEPT# (for C4-36

only)

 

 

5. Digits and display of PLU#.

 

 

 

PLU#

2 3 4

5 6

 

Display

2-l

2-2

2-3

2-4

2-5

2-6

- 58 -

Page 61
Image 61
Toshiba EMl-31015D, SL-5900, EM1-31015 manual Pc/D, Flag PLU# UPC# PC/D