Toshiba EM1-31064JE, SL-9000N-FFB, SL-9000-FFB owner manual Lon System

Models: SL-9000-FFB

1 96
Download 96 pages 56.8 Kb
Page 50
Image 50
11.15 LON SYSTEM

11. PROGRAMMING PROCEDURES

EM1-31064

11.15 LON SYSTEM

11.15 LON SYSTEM

Menu Page:

2

Item No.:

4

The SL-9000 scales which consist of a master, satellites, and a backup master are connected each other by the LON cable to transmit data such as PLU, ING., NUTRI, etc.

ID# 1 is reserved for the master terminal.

ID# 2 is reserved for the backup master terminal or satellite terminal.

ID# 3 to 32 are for satellite terminals.

Setting numbers other than the above results in an error.

 

 

m

<MENU>

4

CHANGE

Page 2

PLU

 

 

 

ID #

ENTER

IN-LINE Manual backgroundManual backgroundOFF-LINE

ID#: 1

Set the number of

scales in the system.

ENTER

DLL? Yes n

No

p

PROG.

ESC.

<MENU>

Page 2

Main

<MENU>

m

NOTES: 1. Before starting the above procedure, press the Manual backgroundManual backgroundManual background key and enter IN-LINE mode.

2.When installing the backup master terminal, set the master scale’s initial status of #9-1 to 1.

3.Set ID # to all scales in a LON system.

4.When the display power is turned on, the satellite terminal is ready to receive data from the master terminal.

5.After setting the ID #, turn the power switch OFF and ON again.

11-24