Model

Model

Number

Description

S F H F C

 

5

5 F H A 5 5 C 6 9 D 3 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 01

1

2

3

4

5

6 7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

28

29

30

31

32

33

34

35

36

37

38

DIGIT 1 — UNIT TYPE

S = Self-Contained (Packaged Rooftop)

DIGIT 2 — UNIT FUNCTION

A = DX Cooling, No Heat

E= DX Cooling, Electric Heat

F= DX Cooling, Natural Gas Heat

L= DX Cooling, Hot Water Heat

S= DX Cooling, Steam Heat

X= DX Cooling, No Heat, Extended Casing

DIGIT 3 — UNIT AIRFLOW

H = Single Zone

DIGIT 4 — DEVELOPMENT SEQUENCE

F = Sixth

DIGITS 5,6,7 — NOMINAL CAPACITY

C20

=

20 Tons

C55

=

55 Tons

C25

=

25 Tons

C60

=

60 Tons

C30

=

30 Tons

C70

=

70 Tons

C40

=

40 Tons

C75

=

75 Tons

C50

=

50 Tons

 

 

 

DIGIT 8 — POWER SUPPLY (See Notes)

4

=

460/60/3 XL

E

=

200/60/3 XL

5

=

575/60/3 XL

F

=

230/60/3 XL

Note: SEHF units (units with electric heat) utilizing 208V or 230V require dual power source.

DIGIT 9 — HEATING CAPACITY

Note: When the second digit calls for “F” (Gas Heat), the following values apply: Additionally, please note G and M available ONLY on 50 Ton models and above.

H = High Heat-2-Stage

P = High Heat-Full

L = Low Heat-2-Stage

Modulation

0 = No Heat

M = Low Heat-Full

J = High Heat-Limited

Modulation

Modulation

 

G = Low Heat-Limited

 

Modulation

 

Note: When the second digit calls for “E” (electric heat), the following values apply:

D

=

30 KW

R

=

130 KW

H

=

50 KW

U

=

150 KW

L

=

70 KW

V

=

170 KW

N

=

90 KW

W =

190 KW

Q

=

110 KW

 

 

 

Note: When the second digit calls for ‘’L’’ (Hot Water) or ‘’S’’(Steam) Heat, one of the following valve size values must be in Digit 9:

High Heat Coil: 1 = .50”, 2 = .75”, 3 = 1”, 4 = 1.25”, 5 = 1.5”, 6 = 2”.

Low Heat Coil: A = .50”, B = .75”, C = 1”, D = 1.25”, E = 1.5”, F = 2”.

DIGIT 10 — DESIGN SEQUENCE

A = First (Factory Assigned)

Note: Sequence may be any letter A thru Z, or any digit 1 thru 9.

20

DIGIT 11 — EXHAUST OPTION

0 = None

1 = Barometric

2= 100%, 1.5 HP W/Statitrac

3= 100%, 3 HP W/Statitrac

4= 100%, 5 HP W/Statitrac

5= 100%, 7.5 HP W/Statitrac

6= 100%, 10 HP W/Statitrac

7= 100%, 15 HP W/Statitrac

8= 100%, 20 HP W/Statitrac A = 50%, 1.5 HP

B = 50%, 3 HP C = 50%, 5 HP D = 50%, 7.5 HP

E= 100%, 1.5 HP W/O Statitrac (CV Only)

F= 100%, 3 HP W/O Statitrac (CV Only)

G= 100%, 5 HP W/O Statitrac (CV Only)

H= 100%, 7.5 HP W/O Statitrac (CV Only)

J= 100%, 10 HP W/O Statitrac (CV Only)

K= 100%, 15 HP W/O Statitrac (CV Only)

L= 100%, 20 HP W/O Statitrac (CV Only)

DIGIT 12 — EXHAUST AIR FAN DRIVE

0

=

None

8 =

800 RPM

4

=

400 RPM

9 =

900 RPM

5

=

500 RPM

A =

1000 RPM

6

=

600 RPM

B =

1100 RPM

7

=

700 RPM

 

 

DIGIT 13 — FILTER

 

 

A =

Throwaway

 

 

B =

Cleanable Wire Mesh

C =

High-Efficiency Throwaway

D =

Bag With Prefilter

 

E =

Cartridge With Prefilter

F= Throwaway Filter Rack Less Filter Media

G= Bag Filter Rack Less Filter Media

DIGIT 14 — SUPPLY AIR FAN HP

 

1

= 3 HP

4 = 10 HP

7

=

25 HP

2

= 5 HP

5 = 15 HP

8

=

30 HP

3

= 7.5 HP

6 = 20 HP

9

=

40 HP3

DIGIT 15 — SUPPLY AIR FAN DRIVE

5 = 500 RPM

B = 1100 RPM

6 = 600 RPM

C = 1200 RPM

7 = 700 RPM

D = 1300 RPM

8 = 800 RPM

E = 1400 RPM

9 = 900 RPM

F = 1500 RPM

A = 1000 RPM

G = 1600 RPM

DIGIT 16 — FRESH AIR

A= No Fresh Air

B= 0-25% Manual

D = 0-100% Economizer

DIGIT 17 — SYSTEM CONTROL

1= Constant Volume Control

2= VAV Supply Air Temperature Control w/o Inlet Guide Vanes

3= VAV Supply Air Temperature Control w/ Inlet Guide Vanes

4= Space Pressure Control with Exhaust VFD w/o Bypass

5= Space Pressure Control with Exhaust VFD and Bypass

6= VAV Supply Air Temperature Control with VFD w/o Bypass

7= VAV Supply Air Temperature Control with VFD and Bypass

8= Supply and Exhaust Fan with VFD w/o Bypass

9= Supply and Exhaust Fan with VFD and Bypass

DIGIT 18 — ACCESSORY PANEL

0 = None

A = BAYSENS008*

B = BAYSENS010*

C = BAYSENS013*

D = BAYSENS014*

E = BAYSENS019*

F= BAYSENS020*

G= BAYSENS021*

DIGIT 19 — AMBIENT CONTROL

0 = Standard

1 = 0° Fahrenheit

DIGIT 20 — AGENCY APPROVAL

0 = None (UL Gas Heater, see note)

1 = UL

2 = CSA

Note: Includes UL classified gas heating section only when second digit of Model No. is a “F.”

DIGITS 21 - 38 — MISCELLANEOUS

21A = Unit Disconnect Switch

22B = Hot Gas Bypass

23D = Economizer Control w/

Comparative Enthalpy 23 R = Economizer Control w/

Reference Enthalpy

23T = Economizer Control w/Dry Bulb

24E = Low Leak Fresh Air Dampers

25F = High Duct Temperature Thermostat

26G = High Capacity Evap. Coil

27H = Copper Fins (Cond. Only)

28K = Generic B.A.S. Module

29L = High-Efficiency Motors (Supply and Exhaust)

30M = Remote Human Interface

31N = Ventilation Override Module

32R = Extended Grease Lines

33T = Access Doors

34V = Inter-Processor Communica tion Bridge

35Y = Trane Communication Interface Module

368 = Spring Isolators

376 = Factory-Powered 15A GFI Convenience Outlet

385 = VFD Line Reactor

RT-PRC010-EN