Trane RT-PRC010-EN manual Model Number Description, G D 1 1

Models: RT-PRC010-EN

1 104
Download 104 pages 11.81 Kb
Page 21
Image 21
G D 1 1 4

Model

Number

Description

S

X H

G D 1 1 4

O A

H 7

C F

9

D

3

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

02

1

2

3

4

567

8

9

10

11 12

13 14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

DIGIT 1 — UNIT TYPE

S = Self-Contained (Packaged Rooftop)

DIGIT 2 — UNIT FUNCTION

E= DX Cooling, Electric Heat

F= DX Cooling, Natural Gas Heat

L= DX Cooling, Hot Water Heat

S= DX Cooling, Steam Heat

X= DX Cooling, No Heat, Extended Casing

DIGIT 3 — UNIT AIRFLOW

H = Single Zone

DIGIT 4 — DEVELOPMENT SEQUENCE

G = Seventh

DIGITS 5,6,7 — NOMINAL CAPACITY

C90 = 90 Tons

D11 = 105 Tons

D12 = 115 Tons

D13 = 130 Tons

DIGIT 8 — POWER SUPPLY

4= 460/60/3 XL

5= 575/60/3 XL E = 200/60/3 XL F = 230/60/3 XL

DIGIT 9 — HEATING CAPACITY

0 = No Heat

H = High Heat - 2-Stage

J= High Heat - Limited Modulation P = High Heat - Full Modulation

Note:

When the second digit calls for “E” (electric heat), the following values apply in the ninth digit:

W = 190 KW

When the second digit calls for ‘’L’’ or ‘’S’’, one of the following valve size values must be in Digit 9:

High Heat Coil: 3 = 1.0”, 4 = 1.25”, 5 = 1.50”, 6 = 2.0”, 7 = 2.5”

Low Heat Coil: C = 1.0”, D = 1.25”, E = 1.50”, F = 2.0”, G = 2.5”

DIGIT 10 — DESIGN SEQUENCE

A = First (Factory Assigned)

Note: Sequence may be any letter A thru Z, or any digit 1 thru 9.

DIGIT 11 — EXHAUST OPTION

0 = None

7 = 100%, 15 HP W/Statitrac

8= 100%, 20 HP W/Statitrac

9= 100%, 25 HP W/Statitrac F = 50%, 15 HP

H = 100%, 30 HP W/Statitrac J = 100%, 40 HP W/Statitrac

K = 100%, 15 HP W/O Statitrac (CV Only) L = 100%, 20 HP W/O Statitrac (CV Only) M = 100%, 25 HP W/O Statitrac (CV Only) N = 100%, 30 HP W/O Statitrac (CV Only) P = 100%, 40 HP W/O Statitrac (CV Only)

DIGIT 12 — EXHAUST AIR FAN DRIVE

0 = None

5= 500 RPM

6= 600 RPM

7= 700 RPM

8= 800 RPM

DIGIT 13 — FILTER

A = Throwaway

C = High-Efficiency Throwaway

D= Bag With Prefilter

E= Cartridge With Prefilter

F= Throwaway Filter Rack Less Filter Media

G= Bag Filter Rack Less Filter Media

DIGIT 14 — SUPPLY AIR FAN HP

C= 30 HP (2-15 HP)

D= 40 HP (2-20 HP)

E= 50 HP (2-25 HP)

F= 60 HP (2-30 HP)

G= 80 HP (2-40 HP)

DIGIT 15 — SUPPLY AIR FAN DRIVE 9 = 900 RPM

A = 1000 RPM

B = 1100 RPM

C= 1200 RPM

D= 1300 RPM

E = 1400 RPM

F = 1500 RPM

G= 1600 RPM

DIGIT 16 — FRESH AIR

D = 0-100% Economizer (Std.)

DIGIT 17 — SYSTEM CONTROL

1= Constant Volume Control

2= VAV Supply Air Temperature Control w/o Inlet Guide Vanes

3= VAV Supply Air Temperature Control w/ Inlet Guide Vanes

4= Space Pressure Control with Exhaust VFD w/o Bypass

5= Space Pressure Control with Exhaust VFD and Bypass

6= VAV Supply Air Temperature Control with VFD w/o Bypass

7= VAV Supply Air Temperature Control with VFD and Bypass

8= Supply and Exhaust Fan with VFD w/o Bypass

9= Supply and Exhaust Fan with VFD and Bypass

DIGIT 18 — ACCESSORY PANEL

0 = None

A = BAYSENS008*

B = BAYSENS010*

C = BAYSENS013*

D = BAYSENS014*

E = BAYSENS019*

F= BAYSENS020*

G= BAYSENS021*

DIGIT 19 — AMBIENT CONTROL

0 = Standard

DIGIT 20 — AGENCY APPROVAL

0= None (UL Gas Heater, see note)

1= UL

2= CSA

Note: Includes UL classified gas heating section only, when second digit of Model No. is a “F.”

DIGITS 21 - 36 — MISCELLANEOUS

21A = Unit Disconnect Switch

22B = Hot Gas Bypass (CV Only)

23D = Economizer Control w/ Comparative Enthalpy

23R = Economizer Control w/ Reference Enthalpy

23T = Economizer Control w/Dry Bulb

24E = Low Leak Fresh Air Dampers

25F = High Duct Temperature Thermostat

26G = High Capacity Evaporator

Coil (90-105 Only)

27

K

= Generic B.A.S. Module

28

L

=

High-Efficiency Motors

 

 

 

(Supply and Exhaust)

29

M

= Remote Human Interface

30

N

=

Ventilation Override Module

31

R

= Extended Grease Lines

32

T

= Access Doors

1.EXAMPLE: Model numbers: SFHFC55FHA55C69D3001N describes a unit with the following characteristics: DX cooling with natural gas heating, 55 ton nominal cooling capacity, 230/60/3 power supply, high heat model. 100 percent exhaust with Statitrac, 7.5 HP exhaust fan motor with drive selection No. 5 (500 RPM), high-efficiency throwaway filters, 20 HP supply fan motor with drive selection No. 9 (900 RPM), 0-100% economizer, VAV supply air temperature control with inlet guide vanes, no remote panel, standard ambient control, U.L. agency approval. The service digit for each model number contains 38 digits; all 38 digits must be referenced.

2.EXAMPLE: Model numbers: SXHGD1140AH7CF8D3001 describes a unit with the following characteristics: DX cooling with extended casing, no heat, 105 ton nominal cooling capacity, 460/60/3 power supply, no heat, 100 percent exhaust with Statitrac, 30 h.p. exhaust fan motor with drive selection No. 7 — (700 RPM), high-efficiency throwaway filters, 60 hp supply fan motor with drive selection No. 8 — (900 RPM), economizer, VAV supply air temperature control with inlet guide vanes, no remote panel, standard ambient, UL agency approval. The service digit for each model number contains 36 digits; all 36 digits must be referenced.

3.Available as standard 460 volt only for 70 and 75 ton models.

33

V

= Inter-Processor

 

 

Communication Bridge

34

Y

= Trane Communication

 

 

Interface Module

35

5

= VFD Line Reactor

36

6

= Factory-Powered 15A GFI

 

 

Convenience Outlet

RT-PRC010-EN

21

Page 21
Image 21
Trane RT-PRC010-EN manual Model Number Description, G D 1 1