Performance
Data
Table
| Gas | Heat | Heat |
|
|
|
|
|
|
|
|
| AirTemperature Rise Vs Unit Cfm |
|
|
|
|
|
|
|
|
|
| ||||||
Nom. | Heat | Input | Output |
|
|
|
|
|
|
|
|
|
|
|
| CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
Tons | Module | (MBh) | (MBh) | 4000 | 5000 | 5760 | 6000 | 6284 | 7000 | 8000 | 9000 | 9792 10000 | 10682 | 10830 11200 | 11750 12000 13500 | 15000 | 16129 | 18000 20000 | 22500 23040 | 25000 | 27000 29377 30000 | ||||||||
20 | Low | 235 | 192.7 | 44 | 36 | 31 | 30 | 28 | 25 | 22 | 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| High | 500 | 410.0 |
|
| 66 | 63 | 60 | 54 | 47 | 42 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25 | Low | 235 | 192.7 |
| 36 | 31 | 30 | 28 | 25 | 22 | 20 | 18 | 18 | 17 | 16 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| High | 500 | 410.0 |
|
| 66 | 63 | 60 | 54 | 47 | 42 | 39 | 38 | 35 | 35 | 34 |
|
|
|
|
|
|
|
|
|
|
|
|
|
30 | Low | 350 | 287.0 |
|
|
| 44 | 42 | 38 | 33 | 29 | 27 | 26 | 25 | 24 | 24 | 23 | 22 | 20 |
|
|
|
|
|
|
|
|
|
|
| High | 500 | 410.0 |
|
|
|
| 60 | 54 | 47 | 42 | 39 | 38 | 35 | 35 | 34 | 32 | 31 | 28 |
|
|
|
|
|
|
|
|
|
|
40 | Low | 350 | 287.0 |
|
|
|
|
|
| 33 | 29 | 27 | 26 | 25 | 24 | 24 | 23 | 22 | 20 | 18 | 16 |
|
|
|
|
|
|
|
|
| High | 850 | 697.0 |
|
|
|
|
|
|
|
| 66 | 64 | 60 | 59 | 57 | 55 | 54 | 48 | 43 | 40 | 36 |
|
|
|
|
|
|
|
50 | Low | 500 | 410.0 |
|
|
|
|
|
|
|
|
| 38 | 35 | 35 | 34 | 32 | 31 | 28 | 25 | 23 | 21 | 19 | 17 |
|
|
|
|
|
| High | 850 | 697.0 |
|
|
|
|
|
|
|
|
|
| 60 | 59 | 57 | 55 | 54 | 48 | 43 | 40 | 36 | 32 | 29 |
|
|
|
|
|
55 | Low | 500 | 410.0 |
|
|
|
|
|
|
|
|
| 38 | 35 | 35 | 34 | 32 | 31 | 28 | 25 | 23 | 21 | 19 | 17 | 16 |
|
|
|
|
| High | 850 | 697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
| 55 | 54 | 48 | 43 | 40 | 36 | 32 | 29 | 28 | 26 |
|
|
|
60 | Low | 500 | 410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 31 | 28 | 25 | 23 | 21 | 19 | 17 | 16 | 15 | 14 |
|
|
| High | 850 | 697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 54 | 48 | 43 | 40 | 36 | 32 | 29 | 28 | 26 | 24 |
|
|
70 | Low | 500 | 410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 31 | 28 | 25 | 23 | 21 | 19 | 17 | 16 | 15 | 14 | 13 | 13 |
| High | 850 | 697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 54 | 48 | 43 | 40 | 36 | 32 | 29 | 28 | 26 | 24 | 22 |
|
75 | Low | 500 | 410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 31 | 28 | 25 | 23 | 21 | 19 | 17 | 16 | 15 | 14 | 13 | 13 |
| High | 850 | 697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 54 | 48 | 43 | 40 | 36 | 32 | 29 | 28 | 26 | 24 | 22 |
|
Notes:
1.All heaters are 82% efficient.
2.Cfm values below the minimums and above the maximums shown in this table are not UL/CSA approved, see
3.Air Temperature Rise = Heat Output (Btu) ÷ (Cfm x 1.085).
Table
| Gas | Heat | Heat |
|
|
| AirTemperature Rise Vs Unit Cfm |
|
|
| ||
Nominal | Heat | Input | Output |
|
|
|
| CFM |
|
|
|
|
Tons | Module | (MBh) | (MBh) | 28,350 | 30,250 | 32,550 | 34,750 | 37,000 | 39,250 | 41,500 | 43,000 | 46,000 |
90 | High | 1000 | 820 | 27 | 25 | 23 | 22 | 20 | 19 | 18 | 18 |
|
105 | High | 1000 | 820 |
|
| 23 | 22 | 20 | 19 | 18 | 18 | 16 |
115 | High | 1000 | 820 |
|
| 23 | 22 | 20 | 19 | 18 | 18 | 16 |
130 | High | 1000 | 820 |
|
| 23 | 22 | 20 | 19 | 18 | 18 | 16 |
Notes:
1.All heaters are 82% efficient.
2.Cfm values below the minimums and above the maximums shown in this table are not UL/CSA approved.
3.Air Temperature Rise = Heat Output (Btu) ÷ (Cfm x 1.085).
Table
20 Nominal Ton Unit |
|
|
|
| 25 Nominal Ton Unit |
|
|
|
| 30 Nominal Ton Unit |
|
|
|
| |||
Steam | Unit Standard Air Volume (Cfm) |
| Steam | Unit Standard Air Volume (Cfm) | Steam | Unit Standard Air Volume (Cfm) | |||||||||||
Module | 4000 | 6000 | 8000 | 10000 |
| Module | 5000 | 7500 | 10000 | 12500 |
| Module | 6000 | 9000 | 12000 | 15000 |
|
Low Heat | 0.95 | 1.18 | 1.37 | 1.52 |
| Low Heat | 1.06 | 1.33 | 1.52 | 1.74 |
| Low Heat | 1.18 | 1.64 | 1.69 | 2.00 |
|
High Heat | 1.94 | 2.47 | 2.95 | 3.31 |
| High Heat | 2.20 | 2.85 | 3.31 | 3.65 |
| High Heat | 2.47 | 3.12 | 3.59 | 3.95 |
|
40 Nominal Ton Unit |
|
|
|
| 50 Nominal Ton Unit |
|
|
|
| 55 Nominal Ton Unit |
|
|
|
| |||
Steam | Unit Standard Air Volume (Cfm) |
| Steam | Unit Standard Air Volume (Cfm) |
| Steam | Unit Standard Air Volume (Cfm |
| |||||||||
Module | 8000 | 12000 | 16000 | 20000 |
| Module | 10000 | 15000 | 20000 | 25000 |
| Module | 11000 | 16500 | 22000 | 27500 |
|
Low Heat | 1.61 | 2.01 | 2.29 | 2.60 |
| Low Heat | 1.82 | 2.21 | 2.60 | 2.85 |
| Low Heat | 1.91 | 2.38 | 2.72 | 2.92 |
|
High Heat | 3.36 | 4.28 | 4.93 | 5.43 |
| High Heat | 3.86 | 4.79 | 5.43 | 5.97 |
| High Heat | 4.09 | 5.01 | 5.64 | 6.41 |
|
60 Nominal Ton Unit |
|
|
|
| 70 & 75 Nominal Ton Unit |
|
|
| 90, 105, 115, 130 Nominal Ton Units |
|
| ||||||
Steam | Unit Standard Air Volume (Cfm) |
| Steam | Unit Standard Air Volume (Cfm) |
| Steam | Unit Standard Air Volume (Cfm) |
| |||||||||
Module | 12000 | 18000 | 24000 | 30000 |
| Module | 16000 | 20000 | 24000 | 30000 |
| Module | 27000 | 33000 | 40000 | 46000 |
|
Low Heat | 2.32 | 2.81 | 3.33 | 3.71 |
| Low Heat | 2.65 | 2.98 | 3.33 | 3.71 |
| Low Heat | 5.17 | 5.70 | 6.19 | 6.53 |
|
High Heat | 3.85 | 4.84 | 5.62 | 6.18 |
| High Heat | 4.50 | 5.10 | 5.62 | 6.18 |
| High Heat | 8.83 | 8.80 | 9.04 | 9.26 |
|
Table
Steam Pressure (Psig) | 2 | 5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 |
Temperature Of Steam (F) | 219 | 227 | 239 | 250 | 259 | 267 | 274 | 287 | 298 |
Note:
1.Capacities expressed as MBH (Q) per initial temperature difference (ITD) between the entering air temperature to the steam module and the entering steam temperature. Maximum recommended operating pressure is 35 PSIG.
41 |