Data

Table PD-35 — Supply Fan PerformanceWITH INLETVANES — 30Ton

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

 

.250

 

.500

 

.750

 

1.000

1.250

1.500

1.750

2.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

6000

327

.53

433

.93

526

1.34

607

1.83

677

2.43

739

3.08

794

3.73

844

4.37

7000

349

.70

440

1.10

529

1.61

608

2.09

679

2.62

743

3.28

801

4.00

853

4.76

8000

376

.94

453

1.34

534

1.85

611

2.45

680

3.00

744

3.57

803

4.24

857

5.02

9000

406

1.25

472

1.64

543

2.15

615

2.77

683

3.45

746

4.06

804

4.68

858

5.36

10000

438

1.63

496

2.02

559

2.54

623

3.13

687

3.85

749

4.60

806

5.30

860

5.97

11000

471

2.09

523

2.49

578

3.00

636

3.60

695

4.29

753

5.08

809

5.91

863

6.70

12000

505

2.62

552

3.05

601

3.56

653

4.17

707

4.84

760

5.60

814

6.46

866

7.37

13000

538

3.24

583

3.72

627

4.22

674

4.82

723

5.51

772

6.26

822

7.09

871

8.01

13500

555

3.59

599

4.08

641

4.59

685

5.19

732

5.89

779

6.64

827

7.45

875

8.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

2.250

 

2.500

 

2.750

 

3.000

3.250

3.500

3.750

4.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

6000

890

5.01

933

5.66

974

6.32

1012

6.99

1049

7.67

1084

8.36

1118

9.08

1151

9.80

7000

902

5.52

947

6.27

989

7.02

1029

7.77

1066

8.52

1102

9.28

1137

10.05

1170

10.83

8000

908

5.85

955

6.71

999

7.58

1041

8.45

1080

9.30

1117

10.16

1152

11.01

1186

11.87

9000

910

6.15

959

7.03

1004

7.96

1048

8.92

1088

9.89

1127

10.87

1164

11.84

1199

12.81

10000

911

6.68

960

7.46

1006

8.34

1050

9.30

1092

10.31

1133

11.36

1171

12.43

1208

13.52

11000

913

7.44

961

8.19

1007

8.97

1051

9.83

1094

10.78

1135

11.81

1174

12.90

1212

14.03

12000

916

8.26

964

9.09

1009

9.90

1053

10.71

1095

11.57

1136

12.49

1175

13.50

1213

14.58

13000

920

8.98

967

9.96

1012

10.90

1055

11.79

1097

12.66

1137

13.54

1176

14.46

1214

15.44

13500

922

9.34

969

10.36

1014

11.37

1057

12.33

1098

13.25

1138

14.16

1177

15.07

1215

16.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cfm

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std

4.250

 

4.500

 

4.750

 

5.000

5.250

5.500

5.750

 

6.000

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

6000

1183

10.54

1213

11.30

1243

12.07

1272

12.86

1300

13.66

1328

14.47

1355

15.30

 

 

7000

1202

11.62

1233

12.42

1263

13.23

1293

14.06

1321

14.90

1349

15.75

1376

16.62

 

 

8000

1219

12.73

1251

13.60

1282

14.47

1311

15.36

1340

16.25

1368

17.15

 

 

 

 

9000

1233

13.77

1266

14.73

1297

15.69

1327

16.66

1357

17.62

 

 

 

 

 

 

10000

1243

14.60

1276

15.68

1309

16.76

1340

17.83

1370

18.90

 

 

 

 

 

 

11000

1248

15.19

1283

16.37

1317

17.56

1349

18.75

 

 

 

 

 

 

 

 

12000

1250

15.73

1286

16.93

1321

18.16

1354

19.42

 

 

 

 

 

 

 

 

13000

1251

16.49

1287

17.61

1322

18.81

1356

20.06

 

 

 

 

 

 

 

 

13500

1252

17.02

1288

18.09

1323

19.23

1357

20.45

 

 

 

 

 

 

 

 

Notes:

1.Shaded areas at table extremes note non-standard Bhp or Rpm selection. Contact your local Trane representative for more information.

2.Supply fan performance table includes internal resistance of rooftop. For total static pressure determination, system external static must be added to appropriate component static pressure drops (evaporator coil, filters, optional economizer, optional exhaust fan, optional heating system, optional cooling only extended casing, optional roof curb).

3.Minimum motor horsepower is 5 hp, maximum motor horsepower is 20 hp. Maximum RPM is 1379.

4.See RT-EB-104 for further details.

50

RT-PRC010-EN

Page 50
Image 50
Trane RT-PRC010-EN manual Performance 30Ton Data, 13500