RECEPTACLES
overload the generator. See "Don't Overload
1201240Volt AC, 30 Amp, Locking Receptacle
Use a NEMA
Cord Set
(Hot) | 1 | X (Hot) |
I NEMA L | T f / Ground (Green) |
This receptacle powers I201240Volt AC, 60 Hz,single phase loads requiring up t o 5,550 watts of power
(5.55 kW) at 23.1 Amps for I2OVolts o r 240Volts.The outlet is protected by a
Use each receptacle t o operate 120Volt AC,
GENERATOR ADAPTER C O R D SET
The getierator is equipped with a 25'generator adapter cord set designed for a 240Volt, 30Amp grounded neutral circuit (Figure 7).The generator adapter.cord set provides a
convenient supply of emergency power into your dwelling so
-
that your generator can be operated safely outside.
120Volt AC, 20 Amp, Duplex
Receptacles-
Each duplex receptacle (Figure 6) is protected against overload by a
The maximum load on each outlet is 2OAmps.The maximum total load on both yellow wire outlets or black wire outlets is 30 Amps.
NOTE: Follow all safety precautions when connecting any extension cord o r device t o the generator.