CLR2060 — Clear Ice Maker

 

 

 

Other Site Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 16.

Water Supply

The unit requires a 1/4-inch OD water supply line and a shut-off valve. For more information see Page 15.

Drain

The unit’s generous 7-inch drain connection height extends the distance the unit can be located from a gravity drain. For more information see Page 12.

IMPORTANT

Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself.

Environmental Requirements

The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). High ambient temperature ranges and warmer water supply will cause reduced ice production. Black and White units may be installed outdoors in a covered area. Stainless Steel CLR2060 units are deemed suitable for outdoor use by UL. The unit must not be located near heat-generating equipment or in direct sunlight.

Side-By-Side Installation

Instructions

For a complete refreshment center, install your CLR2060 Clear Ice Maker beside a U-line Refrigerator, Combo, or Wine Captain Model (see Figure 11 for typical cut-out). Note that each Side-By-Side Installation will be different.

Cut-out width for a side-by-side installation is the total of the widths listed under Cut-Out Dimensions in each unit’s Installation Guide.

For example:

Placing a CLR2060 Clear Ice Maker next to a 2015R Refrigerator would require a cut-out width of:

15-3/16" + 15-3/16" = 30-3/8"

Placing a CLR2060 Clear Ice Maker next to a 2075R Refrigerator would require a cut-out width of:

15-3/16" + 24-3/16" = 39-3/8"

No trim kit is required. However, 1/4-inch space needs to be maintained between the units to ensure unobstructed door swing.

Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s Electrical Specifications.

Typical Side-By-Side Cut-Out

 

 

 

Preferred

 

 

Location

34-1/4"

Acceptable

for CLR2060

Location

Receptacle

to

24"

 

35-1/8"

 

 

 

7"

 

1/4" Space

 

 

Between Appliances

1"

Figure 11

 

www.U-LineService.com

6

02/2005

Page 6
Image 6
U-Line CLR2060 manual Other Site Requirements, Side-By-Side Installation Instructions