INLET SCREEN CLEANING

2.Remove the screws at each end of the grille.

3.Remove the grille.

!WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

4.Clean the condenser coil using a brush or vacuum cleaner. Do not touch.

5.Position the grille to align the screw holes with the cabinet.

6.Insert the grille screws and tighten being careful not to overtighten.

7.Install the control knob by aligning the flat of the control knob with the flat on the shaft. Push firmly.

INLET SCREEN CLEANING

The solenoid valve inlet screen must be cleaned at least once each year as follows:

1.Shut off the water at the water supply valve.

2.Remove the entire hose connector from the solenoid valve.

3.Use a tooth brush to clean sediment from the inlet screen (see Figure 26). DO NOT remove the screen.

4.Attach the hose connector to

the solenoid valve. Tighten con- nector securely with a pliers. Open the water supply valve and check for leakage at the hose connector.

UL123

Figure 26