INSTALLATION

INSTALLATION

SITE PREPARATION

1.Position the unit on a flat, level surface, capable of supporting the entire weight of the unit. Remember the unit will be significantly heavier once it is fully loaded.

2.This unit requires grounded and polarized 115 VAC, 60Hz, 15A circuit (normal household current).

! DANGER !

ELECTROCUTION HAZARD!

Electrical Grounding Required. This appliance is equipped with a three prong (grounding) polarized plug for your protection against possible shock hazards.

NEVER remove the round grounding prong from the plug.

NEVER use a two-prong grounding adapter.

NEVER use an extension cord to connect power to the unit.

Where a two-prong wall receptacle is encountered or a longer power cord is required, contact a qualified electrician to have it replaced in accordance with applicable electrical codes.

NOTE

All U-Line units (except Stainless Steel models) have a zero clearance for the door to open (see Figure 1). See BUILT-IN INSTALLATION for additional clearance require- ments. Stainless steel models require a minimum of 2-1/2" door handle clearance when installed against a wall.

CABINET

OR WALL

DOOR

SWING

0"

CLEARANCE

NEEDED

UL124A

Figure 1